Honeywell Enraf 1010 CB Programming Manual page 27

Load computer
Table of Contents

Advertisement

System (2)
Demonstration Mode Demonstration mode simulates flowmeter input pulses. Demonstration
Automated Proving Enable this function only immediately prior to a Proving Run.
Illegal Access If enabled, the instrument locks out any further use if a pre-programmed
Illegal Retries The number of access attempts allowed before an illegal access is
Alarm on Fault If enabled, under any fault condition (Deadman Terminate, Flow Error,
Ask Compart. No. If enabled, the instrument prompts for the Compartment Number while
4 - 11
Mode is only available via the W&M key to prevent inadvertent access.
Enable
Disable*
Constraints: Only available when you use the Weights and Measures
switch on the instrument to enter programming mode.
Only one arm is allowed to load whilst this function is enabled, even if
Simultaneous Arm Loading is enabled.
For more information, see "Automated Proving" in the Operator Manual.
Select one of the following options:
Enable
Disable*
number of invalid PINs, Touch Keys, NexWatch cards or RF IDs are
read within 5 minutes.
Select one of the following options:
Enable
Disable*
registered.
Constraints: Only if Illegal Access is enabled.
Enter a value in the following range:
3 to 6 (3*)
Temp Error, etc) Programmable GP Output (System Alarm) is closed.
Select one of the following options:
Enable*
Disable
setting up a load.
Ask Compart No prompt is disabled when RIT is enabled. Users can
enable the prompt.
Select one of the following options:
Enable*
Disable
Model 1010 Application Pack CB
Programming Manual
Part No.: 4418024 - Rev. 1