Opto Outputs (28); Opto Outputs - Honeywell Enraf 1010 CB Programming Manual

Load computer
Table of Contents

Advertisement

System (2)
ARM INPUT n After selecting any arm input from the ARM MESSAGES menu, the
NOTE:
Opto Outputs Select one of the following options:
4 - 30
instrument displays the following screen.
This screen allows selection of an entry from a list of choices. Scroll
through list using the DISPLAY key. The list contains standard and fixed
messages.
Select one of the following options:
Standard*
Vapour System
Valve Position
Additive Alarm
Arm Park
Arm Position

4.9 Opto Outputs (28)

The Opto Outputs sub-menu of the System menu allows the operator to
configure the various opto outputs.
This a global parameter. For example, if this parameter is set to Flow meter
B pulses, all Opto Outputs will output the Flow B pulse from their respective
flow meter.

4.9.1 Opto Outputs

Flow meter A
Flow meter A pulses can be provided at the output
Flow meter B
Flow meter B pulses can be provided at the output.