Additive Setup - Honeywell Enraf 1010 CB Programming Manual

Load computer
Table of Contents

Advertisement

Loading Arms (3)
Low Flow Alarm If enabled, the instrument issues an alarm if the low flow limits are
Low Percentage The instrument triggers the low flow low alarm if the arm low flow is less
High Percentage The instrument triggers the low flow high alarm if the arm low flow
Low Flow Alarm Delay The time that the instrument waits until the volume reaches (LOW
Continue Add Batch on
Manual Product Pacing Allows the use of product pacing quantity.
5 - 6
exceeded.
Select one of the following options
ENABLE
DISABLE*
than LOW PRECENTAGE and the low flow alarm is enabled.
Enter a value in the following range:
1.0 to 50.0 (1.0*)
exceeds HIGH PRECENTAGE and the low flow alarm is enabled.
Enter a value in the following range:
1.0 to 50.0 (1.0*)
FLOW ALARM DELAY) before triggering low flow alarm.
Enter a value in the following range:
10 to 300 (10.0*)

5.2.6 Additive Setup

Use the Additive Setup sub-menu to set the volume of product that must
pass through the loading arm for each Additive Injection.
Allows enabling or disabling the Continue Additive Batch on alarm
alarm
feature. When enabled, the additive exception results in an alarm being
registered via the AL command, but the batch will be paused and the
instrument displays an option to restart without the faulty additive.
Constraints: Only available if the arm has internal additives assigned
Select one of the following options:
Enable
Disable*
Constraints: Only available if additive type is selected as external
Select one of the following options:
ENABLE
DISABLE*
Model 1010 Application Pack CB
Programming Manual
and enabled.
additive.
Part No.: 4418024 - Rev. 1