1

Functional Description

1-1. Functional Description
2
Select 1 indicator
(Yellow)
1
Output 1 operation
indicator (Orange)
3
Laser emission
indicator (Green)
Output 1, 2 operation indicator (Orange)......
1
2
Select 1, 2 indicator (Yellow)...............
3
Laser emission indicator (Green).........
4
MODE indicators..............................
Jog switch.......................................
5
6
MODE key.......................................

1-2. Setting Procedure

The use [MODE key] and [Jog switch] are utilized to configure various settings.
1
Press the [MODE key]
(mode selection / cancellation)
Cancel: If the [MODE key] is pressed, the amplifier will return to the previous settings status, immediately before
the [Jog switch] was pressed (the selected setting has been confirmed).
Selection and confirmation of settings are performed according to the order of the numbers, as shown on the amplifier: 1 , 2 and 3 .
Ramco National
2
Select 2 indicator
(Yellow)
1
Output 2 operation
indicator (Orange)
4
MODE indicators
,
and
are in the correct order for selecting settings.
Lights up when output 1 or output 2 is ON.
Lights up when output 1 or output 2 is selected.
Lights up when laser is emitted.
RUN (Green)
: Lights up during normal sensing operation.
TEACH (Yellow)
: When this indicator lights up, in normal mode, the 'threshold
value' can be set by utilizing either '2-level teaching', 'limit
teaching' or 'full-auto teaching'. In window comparator mode
and hysteresis mode, the 'threshold value' can be set by either
'1-level teaching', '2-level teaching' or '3-level teaching'
whenever this indicator lights up. Span adjustment can be carried
out when using rising differential and trailing differential modes.
L/D ON (Yellow)
: When this indicator lights up, the output operation setting can be done.
TIMER (Yellow)
: When this indicator lights up, timer operation and timer period
setting can be done.
CUST (Yellow)
: When this indicator lights up, function is stored in the CUSTOM
mode, can be set.
PRO (Yellow)
: When this indicator lights up, further advanced functions, such
as the copying and memory functions, can be set.
Moving this switch in the '
for selection and pressing the switch then confirms the selected setting.
This key is used to select operating modes and to cancel settings while they are
being configured.
2
Turn the [Jog switch] in the ' ' or
' ' direction (chooses setting for selection)
1
(800) 280-6933
Digital display (Green, Red)
5
Jog switch
' or '
' direction, allows different items to be viewed
3
Press the [Jog switch]
(confirms the selected setting)