Front Panel Operation
Figure 4-12
Digital I/O connections using trigger link cable

4.10 External triggering

The Model 7001 has BNC connectors on the rear panel
(see Figure 4-13) associated with external triggering.
The EXTERNAL TRIGGER input jack allows the Mod-
el 7001 to be triggered by other instruments and the
CHANNEL READY output jack allows the Model 7001
to trigger other instruments.
CHANNEL
READY
Figure 4-13
External triggering connectors (BNC)

4.10.1 External trigger

The EXTERNAL TRIGGER input jack requires a fall-
ing-edge, TTL-compatible pulse with the specifications
shown in Figure 4-14.
4-48
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com
Trigger Link Cable
Cable Plug
1
2
1 = Digital Input
2 = N/C
3 = Voltage Input (up to 30V)
4 = Digital Output #1
5 = Digital Output #2
6 = Digital Output #3
7 = Digital Output #4
8 = Digital Common
EXTERNAL
TRIGGER
3
6
4
7
8
5
Triggers on
Leading Edge
TTL High
(2V-5V)
TTL Low
(≤0.8V)
Minimum
Figure 4-14
External trigger and asynchronous Trigger Link Input
pulse specifications
In general, external triggers can be used as events to
control scan operation. In order for the Model 7001 to
respond to external triggers, the appropriate layers of
scan operation must be configured for it. Paragraph 4.8
explains how to program the three layers of the scan.
2µs