:CYTPe?
Query
command
Short-form formats:
Response message:
After installing a non-701X series card in a mainframe slot, use the :CYTPe command to assign
Description
the ID (identification) number (type) for that slot. For example, if a Model 7156 card is installed
in Slot 1, send type parameter C7156 with the command.
Type C9990 or C9991 can be used to assign a slot as a card simulator. By assigning C9990, the
instrument will operate as if a 40 channel switch card were installed in the specified slot. By
assigning C9991, the instrument will operate as if a 4 x 10 matrix were installed.
A slot assignment change could make a channel that is currently included in the Scan List and/
or a Channel Pattern unavailable. The unavailable channel causes the Scan List and/or the af-
fected Channel Pattern to clear.
Programming
This program assumes that Slot 1 is empty.
example
10
20
30
40
Line 10 Assigns simulator C9990 to Slot 1 and then queries the model number.
Line 20 Addresses the 7001 to talk.
Line 30 Displays the card ID number assigned to Slot 1 (C9990).
:POLE <NRf>
5.13.9
[:ROUTe]:CONFigure:SLOT[1]:POLE <NRf>
[:ROUTe]:CONFigure:SLOT2:POLE <NRf>
Parameters
<NRf> = 1
Short-form
:conf:slot:pole <NRf>
formats
:conf:slot2:pole <NRf>
Power-up
Defaults
*RST
:SYSTem:PRESet
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com
[:ROUTe] subsystem
Query card ID assignment for specified slot.
:conf:slot:ctyp?
:conf:slot2:ctyp?
Assigned card ID (e.g. C7156)
OUTPUT 707; ":conf:slot1:ctyp C9990; ctyp?"
ENTER 707; A$
PRINT A$
END
Select 1-pole mode
= 2
Select 2-pole mode
= 4
Select 4-pole mode
Last selected pole mode for each slot
No effect
No effect
IEEE-488 Reference
Select pole mode for card in Slot 1