www.keithley.com
Series 3700 System Switch/Multimeter
Quick Start Guide
3700S-903-01 Rev. A / August 2007
A
G R E A T E R
M E A S U R E
O F
C O N F I D E N C E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3706 and is the answer not in the manual?

Questions and answers

Summary of Contents for Keithley 3706

  • Page 1 Series 3700 System Switch/Multimeter Quick Start Guide 3700S-903-01 Rev. A / August 2007 G R E A T E R M E A S U R E C O N F I D E N C E...
  • Page 2 WARRANTY Keithley Instruments, Inc. warrants this product to be free from defects in material and workmanship for a period of one (1) year from date of shipment. Keithley Instruments, Inc. warrants the following items for 90 days from the date of shipment: probes, cables, software, rechargeable batteries, diskettes, and documentation.
  • Page 4 Series 3700 System Switch/Multimeter Quick Start Guide ©2007, Keithley Instruments, Inc. All rights reserved. Cleveland, Ohio, U.S.A. Document Number: 3700S-903-01 Rev. A / August 2007...
  • Page 5 Revision includes a revised copy of this print history page. Document Number: 3700S-903-01 Rev. A ........August 2007 All Keithley Instruments product names are trademarks or registered trademarks of Keithley Instruments, Inc. Other brand names are trademarks or registered trademarks of their respective holders.
  • Page 6: Safety Precautions

    Keithley Instruments products are designed for use with electrical signals that are rated Measurement Category I and Measurement Category II, as described in the International Electrotechnical Commission (IEC) Standard IEC 60664. Most measurement, control, and data I/O signals are Measurement Category I and must not be directly connected to mains voltage or to voltage sources with high transient over-voltages.
  • Page 7 To maintain protection from electric shock and fire, replacement components in mains circuits - including the power transformer, test leads, and input jacks - must be purchased from Keithley Instruments. Standard fuses with applicable national safety approvals may be used if the rating and type are the same.
  • Page 8: Table Of Contents

    Table of Contents Introduction Overview ........................1-1 Measure and switching capabilities ................. 1-2 Introduction ........................1-2 User manual content ...................... 1-2 Reference manual content ....................1-3 Warranty information ....................1-3 Displaying the unit's serial number .................. 1-4 Safety symbols and terms .................... 1-4 Using the Front Panel Front panel introduction ....................
  • Page 9 Contents Series 3700 System Switch/Multimeter Quick Start Guide Frequently Asked Questions General questions ......................4-1 How do I power up the instrument? ................. 4-1 How do I control switches? ..................... 4-2 How do I make measurements? ..................4-7 How do I save data to a USB flash drive? ..............4-10 How can I save/recall setups from the internal memory or USB drive? ......
  • Page 10 Figure 2-2: Model 3706-S System Switch (no DMM)............2-2 Figure 2-3: Model 3706-NFP System Switch/Multimeter ............2-2 Figure 2-4: Model 3706-SNFP System Switch (no DMM) ............. 2-3 Figure 2-5: Active channel display example ................. 2-3 Figure 2-6: MAIN MENU display ..................2-6 Figure 3-1: Rear panel features ...................
  • Page 12: Introduction

    The Series 3700 includes four versions of the Model 3706 system switch mainframe along with a growing family of plug-in switch and control cards. When the Model...
  • Page 13: Measure And Switching Capabilities

    Section 1: Introduction Series 3700 System Switch/Multimeter Quick Start Guide Measure and switching capabilities The basic measurement capabilities of Series 3700 systems are summarized in the following figure. Figure 1-1: DMM measurement capabilities Introduction This Quick Start Guide is intended to get a new user familiar with the operation of the instrument.
  • Page 14: Reference Manual Content

    Detailed warranty information is located at the front of this manual. Should your Series 3700 require warranty service, contact the Keithley Instruments representative or authorized repair facility in your area for further information. When returning the instrument for repair, be sure to complete the service form at the back of this manual and give it to the repair facility with all relevant information.
  • Page 15: Displaying The Unit's Serial Number

    Section 1: Introduction Series 3700 System Switch/Multimeter Quick Start Guide Displaying the unit's serial number To display the serial number on the front panel: NOTE If the Series 3700 is in remote mode, press the EXIT key once to place the unit in local mode.
  • Page 16: Using The Front Panel

    Typical Series 3700 front panels are shown below. NOTE Not all models will have a DMM installed. All DMM related documentation is not applicable to those models. Figure 2-1: Model 3706 System Switch/Multimeter Item Description Special keys and power switch (quick start guide) (see "Special keys and power switch"...
  • Page 17: Figure 2-2: Model 3706-S System Switch (No Dmm)

    Section 2: Using the Front Panel Series 3700 System Switch/Multimeter Quick Start Guide Figure 2-2: Model 3706-S System Switch (no DMM) NOTE If your model does not have a front panel, please refer to the reference manual for information on how to change: 1.
  • Page 18: Display

    Series 3700 System Switch/Multimeter Quick Start Guide Section 2: Using the Front Panel Figure 2-4: Model 3706-SNFP System Switch (no DMM) Display The Series 3700 display provides visual information on the present active channel. The display, with the wheel, provides a means to change the active channel or channel ranges, as well as access to view and edit the various menus and menu items.
  • Page 19 Section 2: Using the Front Panel Series 3700 System Switch/Multimeter Quick Start Guide The top line of the display (1) contains the following annunciators: Annunciator Description * (asterisk) Front panel readings are being stored in the selected reading buffer. 4-wire resistance or RTD temperature reading displayed. Unit armed and ready to use.
  • Page 20 Series 3700 System Switch/Multimeter Quick Start Guide Section 2: Using the Front Panel Front pnel DMM atribute Symbol Values thermocouple sensor E E_T/C thermocouple sensor R R_T/C thermocouple sensor S S_T/C thermocouple sensor B B_T/C thermocouple sensor N N_T/C thermistor THRM three-wire RTD 3RTD...
  • Page 21: Front Panel Keys

    Section 2: Using the Front Panel Series 3700 System Switch/Multimeter Quick Start Guide Figure 2-6: MAIN MENU display Front panel keys Special keys and power switch POWER switch: Press this switch to turn the Series 3700 on (I); press it again to turn it off (O). DISPLAY key: Press this key to toggles between main and user display modes.
  • Page 22: Operation Keys

    Series 3700 System Switch/Multimeter Quick Start Guide Section 2: Using the Front Panel Operation keys CHAN key: Pressing this key opens the CHANNEL ACTION MENU that contains the following menu items: OPEN, CLOSE EXCLOSE, EXSLOTCLOSE, and RESET. PATT key: Pressing this key opens the PATTERN ACTION MENU that contains the following menu items: OPEN, CLOSE, EXCLOSE, EXSLOTCLOSE, CREATE, VIEW, DELETE, and RESET.
  • Page 23: Range, Multifunction Keys, And Wheel

    Section 2: Using the Front Panel Series 3700 System Switch/Multimeter Quick Start Guide Range, multifunction keys, and wheel ▲▼ Selects the next higher/lower measurement range for the selected Range keys: function when on measurement display. To set the range, use the RANGE keys ▲ or ▼. If the Series 3700 displays the overflow message on a particular range, select a higher range until an on- range reading is displayed.
  • Page 24 Series 3700 System Switch/Multimeter Quick Start Guide Section 2: Using the Front Panel RATE key: Sets measurement speed (fast, medium, or slow) for the active or selected function. FUNCtion key: This key select the active function by cycling through the following list as listed.
  • Page 26: Rear Panel

    Section 3 Rear Panel In this section: Rear panel summary ..................3-1 Rear panel connections ................... 3-2 Switching module installation and connections ..........3-6 Module installation ..................3-7 Bus operation ....................3-11 Power-up ......................3-12 Rear panel summary Figure 3-1: Rear panel features Item Description Analog backplane fuse...
  • Page 27: Rear Panel Connections

    TYPE AND RATING (3A / 250V). See Fuse replacement for details. Slots Use any of the six slots of the Keithley Instruments Series 3700 for the switching modules. When a module is not installed, make sure to cover the slot with a slot cover. For additional information on an installed module, press the SLOT key.
  • Page 28: Digital I/O Port

    Series 3700 System Switch/Multimeter Quick Start Guide Section 3: Rear Panel Digital I/O port The Series 3700 has a digital input/output port that can be used to control external digital circuitry. For example, a handler that is used to perform binning operations can be used with a Digital I/O port.
  • Page 29: Gpib Connector

    Section 3: Rear Panel Series 3700 System Switch/Multimeter Quick Start Guide Connecting cables Use a cable equipped with a standard male DB-25 connector (Keithley Instruments part number CA-126-1). Digital I/O lines (pins 1 through 14) The port provides 14 digital I/O lines. Each output is set high (+5V) or low (0V) and can read high or low logic levels.
  • Page 30: Analog Backplane Connector

    Series 3700 System Switch/Multimeter Quick Start Guide Section 3: Rear Panel Use the rear connector to communicate with the instrument over USB by sending the desired commands. Use the front panel connector to insert a USB flash drive for saving or loading reading buffers, user setups, or scripts.
  • Page 31: Switching Module Installation And Connections

    Section 3: Rear Panel Series 3700 System Switch/Multimeter Quick Start Guide The table below contains pin numbers and descriptions for the analog backplane connector. Description Description Analog backplane 3-HI DMM-SLO Analog backplane 3-LO DMM-SHI Analog backplane 4-HI DMM-LO 2, 9 Analog backplane 4-LO DMM-HI Analog backplane 5-HI...
  • Page 32: Module Installation

    Series 3700 System Switch/Multimeter Quick Start Guide Section 3: Rear Panel Module installation WARNING Slot covers must be installed on unused slots to prevent personal contact with high voltage circuits. Perform the following steps to install a switching module into the Series 3700 mainframe: 1.
  • Page 33: Figure 3-5: Typical Module Installation

    Section 3: Rear Panel Series 3700 System Switch/Multimeter Quick Start Guide 7. Press the SLOT key to see the model numbers, description, and the firmware revision of the installed switching module(s), along with the mainframe firmware and DMM (if present). Figure 3-5: Typical module installation Item Description...
  • Page 34: Connections

    Series 3700 System Switch/Multimeter Quick Start Guide Section 3: Rear Panel Connections WARNING Connection information for switching modules is intended for qualified service personnel. Do not attempt to connect DUT or external circuitry to a switching module unless qualified to do so. To prevent electric shock that could result in serious injury or death, comply with these safety precautions: Before making or breaking any connections to the switching module,...
  • Page 35: Pseudocards

    Section 3: Rear Panel Series 3700 System Switch/Multimeter Quick Start Guide Pseudocards You can perform open/close/scan operations and configure your system without having an actual switching module installed in your Series 3700. Using remote programming, you can assign a pseudocard to an empty switching module slot, allowing the Model 3700S to operate as if a switching module were installed.
  • Page 36: Bus Operation

    Series 3700 System Switch/Multimeter Quick Start Guide Section 3: Rear Panel Bus operation The Series 3700 supports bus operation over USB, Ethernet and GPIB. The GPIB settings may be set from the front panel, or once controlled by the bus, over the bus. 1.
  • Page 37: Power-Up

    Section 3: Rear Panel Series 3700 System Switch/Multimeter Quick Start Guide The following list contains the four LAN default port numbers (along with corresponding ICLs to query for these values): 1. telnet is 23 (ICL: lan.status.port.telnet) 2. rawsocket is 5025 (ICL: lan.status.port.rawsocket) 3.
  • Page 38: Power-Up Sequence

    Error and status messages contained in the Reference manual.) NOTE If a problem develops while the instrument is under warranty, return it to Keithley Instruments, Inc., for repair. Assuming no errors occur, the Series 3700 will power-up as follows: 1.
  • Page 39: System Identification

    Section 3: Rear Panel Series 3700 System Switch/Multimeter Quick Start Guide 5. The display shows: KEITHLEY Series 3700 6. Main display appears. System identification Serial number, firmware revision, and calibration dates can be displayed by selecting the SYSTEM-INFO item of the main menu (press MENU > SYSTEM-INFO).
  • Page 40: Frequently Asked Questions

    Turn on the instrument by pressing the front panel power switch to the on (I) position. Assuming no errors occur, the Series 3700 will power-up as follows:  The unit will initialize  KEITHLEY SERIES 3700 will be displayed. NOTE The line frequency is automatically sensed at power-up.
  • Page 41: How Do I Control Switches

    Section 4: Frequently Asked Questions Series 3700 System Switch/Multimeter Quick Start Guide How do I control switches? NOTE This paragraph provides information for controlling switches using channel operation (for channel pattern operation, refer to the Channel pattern operation paragraph contained in the User's manual). It contains information on opening and closing all switches from the front panel, as well as over the bus.
  • Page 42 Series 3700 System Switch/Multimeter Quick Start Guide Section 4: Frequently Asked Questions WARNING Careless channel pattern operation could create an electric shock hazard that could result in severe injury or death. Improper operation can also cause damage to the switching modules and external circuitry. Controlling multiple channels using channel patterns should be restricted to experienced test engineers who recognize the dangers associated with multiple channel closures.
  • Page 43 Section 4: Frequently Asked Questions Series 3700 System Switch/Multimeter Quick Start Guide Close/open key operation The front panel CLOSE and OPEN keys operate in the same manner as one of the following:  channel.close and channel.open commands  dmm.close and dmm.open commands The operation of the keys depend on the selected channel or channel patterns function association.
  • Page 44: Figure 4-1: Multiplexer Card Display

    Series 3700 System Switch/Multimeter Quick Start Guide Section 4: Frequently Asked Questions Mux (multiplexer) channel notation To control channels using mux channel notation, use SCCC where: S: Slot number CCC: Channel number (always use 3 digits) Multiplexer examples: Reference Slot Channel 1004 1020...
  • Page 45: Figure 4-2: Matrix Card Display

    Section 4: Frequently Asked Questions Series 3700 System Switch/Multimeter Quick Start Guide Reference Slot Column 3112 6101 Figure 4-2: Matrix card display Channel list parameter <ch_list> The channel list parameter <ch_list>, used when controlling the Series 3700's relays over the bus, is a string-type parameter.
  • Page 46: How Do I Make Measurements

    Series 3700 System Switch/Multimeter Quick Start Guide Section 4: Frequently Asked Questions <ch_list> queries For queries that return a channel list parameter, a channel configured for 4-pole operations will indicate the paired channel in parenthesis. For example, Channel 3003 on a 60-channel card is configured for 4-pole, then sending: channel.close('3003') print(channel.getclose('slot3') ...
  • Page 47: Figure 4-4: Two-Wire Switching Module Resistance Connection

    Section 4: Frequently Asked Questions Series 3700 System Switch/Multimeter Quick Start Guide  Select the 2-wire resistance measurement function by pressing the FUNC key until twowireohms is displayed.  Select the measurement range with the RANGE keys. For the purposes of this example, press AUTO RANGE, and note the AUTO annunciator turns on.
  • Page 48 Series 3700 System Switch/Multimeter Quick Start Guide Section 4: Frequently Asked Questions How do I create a scan (with reading buffer)? NOTE A reading buffer has to be created and selected before it can be used to store data. To create a scan that sends it's measured readings to a reading buffer: 1.
  • Page 49: How Do I Save Data To A Usb Flash Drive

    Section 4: Frequently Asked Questions Series 3700 System Switch/Multimeter Quick Start Guide How do I save data to a USB flash drive? NOTE A reading buffer has to be created, selected, and must contain data before it can be saved to a USB flash drive. To save a reading data buffer to an attached USB flash: 1.
  • Page 50 Series 3700 System Switch/Multimeter Quick Start Guide Section 4: Frequently Asked Questions Recall a setup (bus operation) Setups are recalled over the bus from either internal memory or from a connected USB flash drive. Recalling a setup also may be used to reset to the factory default setup. To recall a setup over the bus, use the following command: setup.recall(location) setup.recall...
  • Page 51: Questions About Web Page Operation

    Section 4: Frequently Asked Questions Series 3700 System Switch/Multimeter Quick Start Guide Figure 4-5: Setup menu Questions about web page operation How do I connect to the internal web page? To connect to the Series 3700 web page, open the Series 3700 IP address with a web browser. The IP address can be found by performing the following procedure: 1.
  • Page 52: What Am I Able To Do Through The Web Page

    Series 3700 System Switch/Multimeter Quick Start Guide Section 4: Frequently Asked Questions How do I change the Series 3700 LAN parameters? To change the Series 3700 LAN parameters: 1. Press the MENU key. 2. Select LAN and press the ENTER key. 3.
  • Page 53: Figure 4-7: Home Page

    Section 4: Frequently Asked Questions Series 3700 System Switch/Multimeter Quick Start Guide NOTE For proper operation of the Web interface after each firmware update, you must change the browser refresh policy. The following procedure is for Internet Explorer (for other browsers, use the procedure as a guideline): 1.
  • Page 54: Questions About Remote Operation

    Sun Java Runtime Environment (JRE)(version 1.6 or above) as a web browser plug-in in the computer that is connected to the instrument. The Series 3700 Product Information CD-ROM that accompanied your Keithley Instruments Series 3700 contains a Java Runtime Environment Update. This JRE contains the Java virtual machine, runtime class libraries, and Java applications browser plug-in necessary to run the program that accesses and controls the instrument through the LXI Web interface.
  • Page 55: Figure 4-8: Gpib Cable

    Series 3700 System Switch/Multimeter Quick Start Guide GPIB interface connection Use a shielded IEEE-488 cable such as the Keithley Instruments Model 7007 to connect the Series 3700 IEEE-488 connector to the GPIB connector on the control computer. Connect one end of the cable to the host computer and the other end to the Series 3700. Both cable connections (see item 1 in the figure titled "GPIB cable") are identical.
  • Page 56: How Do I Use Test Script Builder

    Use the following four steps as a guideline for Test Script Builder operation. Step 1: Run Test Script Builder Run the Test Script Builder program in the Keithley Instruments folder in the usual manner. The main sections of the screen are contained in TSB main sections (on page 4-19).
  • Page 57 Section 4: Frequently Asked Questions Series 3700 System Switch/Multimeter Quick Start Guide  USB: With TSB installed, the USB driver aspects will installed when USB cable from unit is plugged into PC. Once connected, USB0 option for device will appear in list when select Open Instrument choice.
  • Page 58: Tsb Main Sections

    Series 3700 System Switch/Multimeter Quick Start Guide Section 4: Frequently Asked Questions TSB main sections The main sections of the screen are briefly described below. TSB menu bar Main menu items include the following:  File: Allows you to control projects and files. ...
  • Page 59: How Can I Use Tsb To Make Measurements

    Section 4: Frequently Asked Questions Series 3700 System Switch/Multimeter Quick Start Guide Language Help: Provides online help to the TSL programming language. Control icons Control icons include: 1. Open/Close Instrument: Opens instrument resource if closed. Closes instrument resource if open. 2.
  • Page 60: How Do I Use Other Programs

    Series 3700 System Switch/Multimeter Quick Start Guide Section 4: Frequently Asked Questions The next example will configure the DMM the same as the above, except it will create a reading buffer and store the 10 readings in that buffer: Command Description reset() Reset the instrument.
  • Page 61 Series 3700 System Switch/Multimeter Quick Start Guide Examples Below is an example of how to send a reset command via GPIB in Visual Basic to a Model 3706 at GPIB address 16, using the Keithley/CEC GPIB card driver: dim intStatus as integer call Send (16, "reset()", intStatus)
  • Page 62 Series 3700. This statement essentially serves as the query function for the Series 3700. The following example demonstrates how to use the Keithley Instruments GPIB card in Visual Basic to initiate and return a DMM measurement: dim intNumBytes as Integer, intStatus as Integer dim strReading as String call Send (16, "print(dmm.measure())", intStatus)
  • Page 63: Questions About Test Script Processor Interaction

    Keithley Instruments will be posting approved user scripts donated by registered users on its web site. You will be able to download these user scripts into your Series 3700. Visit www.keithley.com for details.
  • Page 64: How Do I Interact With Scripts From Test Script Builder

    Series 3700 System Switch/Multimeter Quick Start Guide Section 4: Frequently Asked Questions Procedure to run scripts from front panel 1. Press the LOAD key to display the LOAD TEST menu. 2. Position the blinking cursor on the USER or SCRIPTS menu item and press the ENTER key (or the Wheel).
  • Page 65 Section 4: Frequently Asked Questions Series 3700 System Switch/Multimeter Quick Start Guide Telnet session example: The following is an example from a telnet session that creates a script called slotquery that will print out the identification strings of each module installed in a slot: loadscript slotquery >>>>...
  • Page 66 Series 3700 System Switch/Multimeter Quick Start Guide Section 4: Frequently Asked Questions Front panel operation 1. Press the EXIT key if not in local operation. 2. Press the LOAD key. 3. Select the SCRIPTS option. 4. Scroll through the list scripts and select (press the ENTER key). The script is now loaded for front panel use.
  • Page 68 Index +5V output (pins 22, 23, and 25) • 3-4 Deleting a user script • 4-27 Digital I/O lines (pins 1 through 14) • 3-4 < Digital I/O port • 3-1, 3-3 <ch_list> queries • 4-7 Display • 2-1, 2-3 Displaying the unit's serial number •...
  • Page 69 Home page • 4-14 Matrix card notation • 3-10, 4-5 Measure and switching capabilities • 1-2 How can I save/recall setups from the internal memory or USB drive? • 4-10 Module installation • 3-7 How can I use TSB to make measurements? • 4-20 Mux (multiplexer) channel notation •...
  • Page 70 Rear panel summary • 3-1, 3-13, 4-16 Recall a setup (bus operation) • 4-11 TSB main sections • 4-17, 4-19 Reference manual content • 1-3 TSB menu bar • 4-19 Remote programming • 4-25 TSP-Link connector • 3-1, 3-2 Returning data from the Series 3700 • 4-23 Running a user script •...
  • Page 71 Service Form Model No. Serial No. Date Name and Telephone No. Company List all control settings, describe problem and check boxes that apply to problem. ❏ ❏ ❏ Intermittent Analog output follows display Particular range or function bad; specify ❏ ❏...
  • Page 72 This page left blank intentionally .
  • Page 73 M E A S U R E C O N F I D E N C E Keithley Instruments, Inc. Corporate Headquarters • 28775 Aurora Road • Cleveland, Ohio 44139 • 440-248-0400 • Fax: 440-248-6168 • 1-888-KEITHLEY • www.keithley.com 12/06...

This manual is also suitable for: