OUTPUT COMP function
5
E Level meters
These meters indicate the amount of gain reduction
(GR), the peak level before (PRE) and after (POST) the
compressor, and the peak level of the key-in signal
(KEY IN) that causes the compressor to operate. If the
signal clips, the OVER segment will light.
If stereo link is turned on for the corresponding MIX
channel or MATRIX channel (or if a STEREO A/B
channel is selected), level meters for two channels are
displayed.
Hint
If GR METER ON/OFF LINK is turned on in the PREFER-
ENCE 1 screen (UTILITY function), the gain reduction meter
will not be displayed when the compressor is off.
6
7
F Type
Indicates the type of the currently selected compressor.
Hint
To change the compressor type, use the OUTPUT COMP
LIBRARY screen to recall a library item that has a different
type. You cannot change the compressor type in this screen.
G STEREO LINK
This specifies whether parameter settings and compres-
sor operation by a key-in signal will be linked
(STEREO LINK button on) for adjacent odd-num-
bered/even-numbered MIX/MATRIX channels or the
L/R channels of the STEREO A/B channels, or not
(STEREO LINK button off).
254
PM5D/PM5D-RH V2 / DSP5D Owner's Manual
8
9
Reference section
❏ Key-in signal flow when Link= On
LINK= ON
THR
Key-in signal of odd-
Detect the
numbered channel
maximum
THR
Key-in signal of even-
numbered channel
❏ Key-in signal flow when Link= Off
LINK= OFF
THR
Key-in signal of odd-
Detect the
numbered channel
maximum level
THR
Detect the
Key-in signal of even-
numbered channel
maximum level
Note
Stereo Link is fixed at On for paired channels and for STE-
REO A/B channels.
H Compressor graph
This graph displays the approximate response of the
compressor.
I KEY IN SOURCE
Select the desired key-in signal from the following
choices.
The pre-EQ signal of the currently
SELF PRE EQ
selected output channel
The post-EQ signal of the currently
SELF POST EQ
selected output channel
MIX1–24 POST EQ
The post-EQ signal of the corre-
sponding output channel (however,
MATRIX1–8 POST EQ
you can only select from the group
to which that channel belongs,
ST AL/AR POST EQ
from the three groups MIX 1–12,
ST BL/BR POST EQ
MIX 13–24, and MATRIX/ST)
The output signal of the corre-
MIX21–24
sponding MIX channel immedi-
ately before the output patch
ATTACK
GR
processing
level
ATTACK
GR
processing
ATTACK
GR
processing
ATTACK
GR
processing

Advertisement