Table 4-4 Aux Output And Isol Connector Pins And Functions J3 - Xantrex Watt Series Programmable DC Power Supply XG 850 Operating Manual

Xg 850 watt series programmable dc power supply
Table of Contents

Advertisement

Table 4-4 AUX Output and ISOL Connector Pins and Functions J3

PIn
Reference
J3.1
AUX_ON_OFF
J3.2
COM_ISOLATED
J3.3
IS_VOL_PR_VOL
J3.4
IS_VOL_PR_CUR
J3.5
1
IS_MON_VOL
J3.6
COM_ISOLATED
J3.7
ISO_CUR_RES_PR
J3.8
ISO_VOL_RES_PR
J3.9
2
+AUX 1
J3.10
1
IS_MON_CUR
J3.11
2
+AUX 2
J3.12
SD
J3.13
PS_GOOD
J3.14
INTER_LOCK 1
J3.15
INTER_LOCK 2
1.Important: Isolated monitor lines are only valid when Isolated analog programming modes are
used for the respective voltage and current control. If local control, digital control or non-iso-
lated APG is used, the non-isolated monitor lines should be used as the isolated monitor lines
will not accurately reflect the output state of the power supply.
2.Use unshielded cable up to 9.84 feet (3 m) length with high-density D-Sub type connector and
a ferrite bead (Fair-Rite part number 0443164251).
M370078-01
Isolated Analog Programming Mode (ISOL)
Function
Auxiliary enable/disable
Isolated Common (Isolated from Main Output and Communication.
Return wire for +5 V, +15 V Auxiliary Voltage.
Isolated Analog Voltage Programming Input
Isolated Analog Current Programming Input
Isolated Voltage Monitor. Scaled to the value of the Voltage Analog
Programming Level.
Isolated Common (Isolated from Main Output and Communication.
Return wire for control signals, monitoring and programming.
Isolated Current Resistive Programming
Isolated Voltage Resistive Programming
+5 V Isolated Output
Isolated Current Monitor. Scaled to the value of the Voltage Analog
Programming Level.
+15 V Isolated Output
Shutdown. Input to power supply to disable output. This input has
user selectable negative logic operation via front panel or remote
digital input/output.
PS_GOOD. Power supply output enabled.
Interlock. Dry contact type. Shorting pins J3.14 and J3.15 with the
interlock functionality enabled will disable the output of the power
supply.
Interlock
4