Device-Specific Error List; Table B-3 Device-Specific Error List - Xantrex Watt Series Programmable DC Power Supply XG 850 Operating Manual

Xg 850 watt series programmable dc power supply
Table of Contents

Advertisement

Table B-2 Execution Error List
Error Code Error Message Description
-222
-224
-291

Device-Specific Error List

An error in the range [-399, 300] or [1, 32767] indicates that the
instrument has detected an error which is not a command error, a query
error, or an execution error; some device operations did not properly
complete, possibly due to an abnormal hardware or firmware condition.
These codes are also used for self-test response errors. The occurrence of
any error in the class causes the device-specific error bit (bit 3) in the
Event Status Register to be set.

Table B-3 Device-Specific Error List

Error Code Error Message Description
-300
-350
-360
-363
-365
M370078-01
Data out of range
Indicates that a legal program data element was parsed but
could not be executed because the interpreted value was
outside the legal range as defined by the device (see IEEE
488.2, 11.5.1.1.5)
Illegal parameter value
Used where the exact value, from a list of possible values, was
expected.
Out of memory
Used when the Autosequence programming buffer is full.
Device-specific error.
Indicates that the power supply could not complete the
operation due to some condition of the power supply.
Queue Overflow
A specific code entered into the queue in lieu of the code that
caused the error. This code indicates that there is no room in the
queue and an error occurred but was not recorded.
Communication error
This is the generic communication error for devices.
Input buffer overrun
Software or hardware input buffer on serial port overflows with
data caused by improper or nonexistent pacing.
Time out error
This is a generic device-dependent error.
Error Messages
B
B-5

Hide quick links: