Resistive-Controlled Current Isol Setup - Xantrex Watt Series Programmable DC Power Supply XG 850 Operating Manual

Xg 850 watt series programmable dc power supply
Table of Contents

Advertisement

Resistive-Controlled Current ISOL Setup

Activating ISOL Resistive-Controlled Current Setup
1. Turn the 9-position mode control to the CAP position or press the
2. Turn rotary Adjust/Enter control to select R IS (voltage source
3. Press the rotary Adjust/Enter control to commit the selected mode.
4. Select the input source level using the rotary Adjust/Enter control.
5. Once the desired level has been selected, press the rotary Adjust/
Deactivating ISOL Current Mode
To deactivate the ISOL current mode:
1. Turn the 9-position mode control to the CAP position or press the
2. CAPr is displayed on the output voltage display.
3. Turn the rotary Adjust/Enter control to select nonE.
4. Press the rotary Adjust/Enter control to commit the change.
M370078-01
rotary Adjust/Enter control if the control knob is already at the CAP
position.
CAPr is displayed on the output voltage display.
from isolated connector).
LE C is displayed on the output voltage display.
Enter control to commit the change.
The display will return to the normal display.
rotary Adjust/Enter control if the control knob is already at the CAP
position.
The display will return to the normal display.
Isolated Analog Programming Mode (ISOL)
4
4-31