User Setting Memory Locations; Saving User Setting Memory Locations; Table 3-8 User Accessible Saved/Recalled Settings - Xantrex Watt Series Programmable DC Power Supply XG 850 Operating Manual

Xg 850 watt series programmable dc power supply
Table of Contents

Advertisement

User Setting Memory Locations

There are three user setting memory locations available for storing
frequently used configurations. These user setting memory locations help
to facilitate multiple users of an XG power supply who have different
setups or when multiple loads are used that have different requirements.
Table 3-8 lists the values that are stored in each user setting memory
location.

Table 3-8 User Accessible Saved/Recalled Settings

Voltage Setpoint
Current Setpoint
Over Voltage Protection (OVP)
Over Temperature Protection (OTP)
Autostart OUTPUT ENABLE Main
Autostart OUTPUT ENABLE Aux
Foldback Mode
Foldback Delay
Shutdown Logic
Voltage Analog Programming (VAP) Mode
Voltage Analog Programming (VAP) Level
Current Analog Programming (CAP) Mode
Current Analog Programming (CAP) Level
Alarm Latches
Front Panel Timeout

Saving User Setting Memory Locations

To save user setting memory locations:
1. Turn the 9-position mode control to the SAV position.
2. Turn the rotary Adjust/Enter control to select a preset position from 1
3. Press the rotary Adjust/Enter control.
M370078-01
SAUE is displayed on the output voltage display with a number
indicating a preset position which is displayed on the output current
display.
to 3.
SAuE done is displayed on the output voltage display.
User Setting Memory Locations
3
3-35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents