Setting Foldback Mode - Xantrex Watt Series Programmable DC Power Supply XG 850 Operating Manual

Xg 850 watt series programmable dc power supply
Table of Contents

Advertisement

Setting Foldback Mode

Foldback mode is used to disable the output when a transition is made
between the operating modes. The power supply will turn off/disable the
output and lock in foldback mode after a specified delay if the power
supply transitions into CV mode or into CC mode, depending on the
foldback mode settings. This feature is particularly useful for protecting
current or voltage sensitive loads. Foldback can be set to trigger a switch
when transitioning from CV to CC mode or from CC to CV mode.
To set the foldback protection and foldback delay time:
1. Turn the 9-position mode control to the FLD position or press the
2. Select the type of crossover that will cause foldback to trigger by
3. Press the rotary Adjust/Enter control when the desired mode has been
4. Adjust the desired delay time using the rotary Adjust/Enter control.
5. Once the desired foldback delay time has been selected, press the
To disable foldback protection:
1. Turn the 9-position mode control to the FLD position or press the
2. FLd is displayed on the output voltage display and the output current
3. Turn the rotary Adjust/Enter control until nonE is displayed in the
M370078-01
rotary Adjust/Enter control if the 9-position mode control is already
at the FLD position.
using the rotary Adjust/Enter control.
If the mode selected is CC or CV mode, the foldback delay timer will
start on a transition into the selected mode. If the mode selected is
none, foldback is not enabled.
selected.
The FLD LED will illuminate and DELA will be displayed in the
output voltage display.
The range can be set from 0.50 seconds to a maximum of 50 seconds.
The step size is in increments of 0.05 seconds when setting from 0.50
to 5 seconds and then in 1 second increments from 5 seconds to 50
seconds.
rotary Adjust/Enter control to commit the foldback delay setting.
rotary Adjust/Enter control if the control knob is already at the FLD
position.
display shows the current foldback trigger mode.
output current display.