Local Operation

Resetting Activated Foldback Protection

3-24
4. Press the rotary Adjust/Enter control to commit the setting once the
desired value has been set.
5. The green FLD LED will turn off and the display will return to the
normal display mode.
The SCPI command (s) for these instructions are:
[:]OUTPut[<channel>]:PROTection:FOLDback[:MODE]
[:]OUTPut[<channel>]:PROTection:FOLDback:LATCh
If you set foldback while the output is enabled and the trigger you
Important:
select is the same as the current operating mode, the foldback timer will begin
counting immediately after the delay time has been set.
To reset activated and latched foldback protection, press and hold the
rotary Adjust/Enter control for approximately 3 seconds.
The SCPI command (s) for these instructions are:
[:]OUTPut[<channel>]:PROTection:CLEar