Table 18: Process Image - I/O Module 750-486 - WAGO 750-486 Manual

4ai 0/4-20 ma, ex i, 4-channel analog input, 0/4-20 ma, namur ne43, ex i for wago-i/o-system 750
Table of Contents

Advertisement

34
Process Image
Table 18: Process Image – I/O Module 750-486
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Byte 9
Byte 10
Byte 11
1)
CHx_Sx = Status byte x from channel x
CHx_D0 = Low byte for process value for channel x
CHx_D1 = High byte for process value for channel x
2)
CHx_Cx = Control byte x from channel x
Manual
Version 1.1.2
1)
Input
Status byte CH1_S0
Function of status byte: Process
value CH1_D0
Function of status byte: Process
value CH1_D1
Control byte CH2_S1
Function of status byte: Process
value CH2_D0
Function of status byte: Process
value CH2_D1
Control byte CH3_S2
Function of status byte: Process
value CH2_D0
Function of status byte: Process
value CH2_D1
Control byte CH4_S3
Function of status byte: Process
value CH4_D0
Function of status byte: Process
value CH4_D1
750-486 4AI 0/4-20 mA, Ex i
Process Image
Byte 0
Control byte CH1_C0
Byte 1
Function of control byte:
Reserved
Byte 2
Function of control byte:
Reserved
Byte 3
Control byte CH2_C1
Byte 4
Function of control byte:
Reserved
Byte 5
Function of control byte:
Reserved
Byte 6
Control byte CH3_C2
Byte 7
Function of control byte:
Reserved
Byte 8
Function of control byte:
Reserved
Byte 9
Control byte CH4_C3
Byte 10
Function of control byte:
Reserved
Byte 11
Function of control byte:
Reserved
WAGO-I/O-SYSTEM 750
2)
Output

Advertisement

Table of Contents
loading