Overview; Table 23: Process Image - I/O Module 750-486/040-000 - WAGO 750-486/040-000 Manual

4ai 0/4-20ma ne43 ex i xtr 4-channel analog input; 0/4...20 ma; ne43; intrinsically safe; extreme for wago-i/o-system 750 xtr
Table of Contents

Advertisement

WAGO-I/O-SYSTEM 750 XTR
750-486/040-000 4AI 0/4-20mA NE43 Ex i XTR
4.1

Overview

Presentation of control/status bytes a function of fieldbus
coupler/controller!
The I/O module always makes its complete process image incl. control/status
bytes available to the fieldbus coupler/controller. The WAGO-I/O-CHECK
commissioning tool accesses the complete commissioning process image. The
fieldbus coupler/controller uses a different process image to stage cyclic process
data via the fieldbus. In the other process image, depending on the fieldbus
coupler/controller, the representation of control/status bytes can be suppressed.
Table 23: Process Image – I/O Module 750-486/040-000
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
...
Byte 21
Byte 22
Byte 23
1)
CHx_Sx = Status byte x from channel x
CHx_D0 = Low byte for process value for channel x
CHx_D1 = High byte for process value for channel x
2)
CHx_Cx = Control byte x from channel x
1)
Input
Status byte CH1_S0
Function of status byte: Process
value CH1_D0
Function of status byte: Process
value CH1_D1
Control byte CH2_S1
Function of status byte: Process
value CH2_D0
Function of status byte: Process
value CH2_D1
...
Control byte CH8_S7
Function of status byte: Process
value CH8_D0
Function of status byte: Process
value CH8_D1
Process image
Byte 0
Control byte CH1_C0
Byte 1
Function of control byte:
Reserved
Byte 2
Function of control byte:
Reserved
Byte 3
Control byte CH2_C1
Byte 4
Function of control byte:
Reserved
Byte 5
Function of control byte:
Reserved
...
...
Byte 21
Control byte CH8_C7
Byte 22
Function of control byte:
Reserved
Byte 23
Function of control byte:
Reserved
Process Image
37
2)
Output
Manual
Version 1.0.0

Advertisement

Table of Contents
loading