Figure 15: Power Supply Concept For Marine Applications In Ex I - Class A (Shown With 750-624/Xxx-Xxx For Field 2); Table 29: Legend For Figure "Power Supply Concept For Marine Applications In Ex I - Class A (Shown With 750-624/Xxx-Xxx For Field 2); Table 30: Explanation Of The Legend For Figure "Power Supply Concept For - WAGO 750-486 Manual

4ai 0/4-20 ma, ex i, 4-channel analog input, 0/4-20 ma, namur ne43, ex i for wago-i/o-system 750
Table of Contents

Advertisement

WAGO-I/O-SYSTEM 750
750-486 4AI 0/4-20 mA, Ex i
Power Supply Concept for Marine Applications in Ex i Class A
Figure 15: Power Supply Concept for Marine Applications in Ex i – Class A (shown with 750-
624/xxx-xxx for Field 2)
Table 29: Legend for figure "Power Supply Concept for Marine Applications in Ex i – Class A (shown
with 750-624/xxx-xxx for Field 2)"
No.
Explanation
1
Fieldbus Couplers/Controllers
2
Filter module, 24 VDC, HI GF (750-626/020-002) or
Filter module, 24 VDC, HI (750-626/020-000) or
Filter module, 24 VDC, HI / T (750-626/025-001)
3
Supply module, 24 VDC (750-602) or
Supply module, 24 VDC, with fuse (750-601) or
Supply module, 24 VDC, with fuse and diagnostics (750-610)
4
Filter module, 24 VDC, HI GF (750-624/020-002) or
Filter module, 24 VDC, HI (750-624/020-000)
5
Supply module, 24 VDC, Ex i, with diagnostics (750-606) or
Supply module, 24 VDC, Ex i (750-625/000-001)
6
Ex I I/O modules
7
End module
Table 30: Explanation of the Legend for figure "Power Supply Concept for Marine Applications in Ex i
– Class A (shown with 750-624/xxx-xxx for Field 2)"
Explanation
HI
High Isolation (filter for isolation-monitored systems)
GF
Ground Fault (filter with ground fault diagnostics)