Sign In
Upload
Manuals
Brands
Daikin Manuals
Fan
VAM350J8VEB
Daikin VAM350J8VEB Manuals
Manuals and User Guides for Daikin VAM350J8VEB. We have
3
Daikin VAM350J8VEB manuals available for free PDF download: Manual, Service Manual, Installation And Operation Manual
Daikin VAM350J8VEB Manual (112 pages)
Heat reclaim ventilation unit
Brand:
Daikin
| Category:
Fan
| Size: 6.31 MB
Table of Contents
Table of Contents
2
About the Documentation
5
About this Document
5
Meaning of Warnings and Symbols
6
General Safety Precautions
8
For the Installer
8
General
8
Installation Site
9
Electrical
9
Specific Installer Safety Instructions
12
For the User
16
User Safety Instructions
17
General
17
Instructions for Safe Operation
18
User Interface
20
Operation
21
Before Operation
21
Operation Range
21
Ventilation Mode
21
To Set the Ventilation Mode
22
Ventilation Rate
22
To Set the Ventilation Rate
22
Energy Saving and Optimum Operation
24
Maintenance and Service
25
Maintenance of the Air Filter
25
Maintenance of the Heat Exchange Element
27
Troubleshooting
28
Relocation
30
Disposal
31
For the Installer
32
About the Box
33
Overview: about the Box
33
Heat Reclaim Ventilation Unit
34
To Unpack the Heat Reclaim Ventilation Unit
34
To Remove the Accessories
36
To Handle the Heat Reclaim Ventilation Unit
37
About the Units and Options
38
Overview: about the Units and Options
38
Identification
38
Identification Label: Heat Reclaim Ventilation Unit
38
About the Heat Reclaim Ventilation Unit
39
About the EKVDX Option
39
Combining Units and Options
40
Possible Options for the Heat Reclaim Ventilation Unit
40
Unit Installation
42
Preparing the Installation Site
42
Installation Site Requirements for the Heat Reclaim Ventilation Unit
42
Preparing the Unit
42
To Install the Optional Adapter PCB
43
To Install the Duct Flanges
45
To Install the EKVDX Option
45
Unit Orientation
46
To Install the Anchor Bolts
47
Duct Connections
48
Electrical Installation
50
About Connecting the Electrical Wiring
50
Precautions When Connecting the Electrical Wiring
50
Guidelines When Connecting the Electrical Wiring
51
Wiring Connection
51
Component Electrical Specifications
52
Specifications for Field Supplied Fuses and Wires
53
Opening the Switch Box
54
Electrical Connections for Additional Field Supplied Damper
61
To Connect the Electrical Wiring
61
To Connect the Monitoring Output
63
System Configuration
64
About Control Systems
64
Independent System
65
Linked Operation Control System
65
Central Control System
66
EKVDX Option
67
Configuration
69
To Change Settings
69
Case 1: Change Settings with BRC1E53
69
Case 2: Change Settings with BRC301B61
70
Case 3: Change Settings with BRC1H
71
Field Settings
72
Settings for All Configurations
74
Field Settings
74
About Setting 19(29)-0-04 and 19(29)-0-05
75
Independent System
75
1-Group Linked-Control System
76
Linked Control with more than 2 Groups
76
Direct Duct Connection
77
Central Control System
78
EKVDX Option - Extra Settings
81
About the Controller
82
BRC1E53 Controller
82
BRC301B61 Controller
85
BRC1H Controller
87
Detailed Explanation of Settings
88
About Fresh-Up Operation
88
About the External Damper Operation
89
About the CO₂ Sensor
90
About Nighttime Free Cooling Operation
94
About the Precool and Preheat Function
95
About Preventing a Feeling of Draft
95
About 24-Hour Ventilation
95
About the Ultra-Low Setting
96
About the Electrical Heater Operation
96
About External Linkage Input
96
About Filter Contamination Check
96
Commissioning
97
Overview: Commissioning
97
Checklist before Commissioning
97
Checklist During Commissioning
98
About the Test Run
98
Hand-Over to the User
99
Maintenance and Service
100
Overview: Maintenance and Service
100
Maintenance Safety Precautions
100
To Prevent Electrical Hazards
100
Checklist for Maintenance of the Heat Reclaim Ventilation Unit
101
Troubleshooting
102
Overview: Troubleshooting
102
Precautions When Troubleshooting
102
Solving Problems Based on Error Codes
102
Error Codes: Overview
102
Disposal
104
Technical Data
105
Wiring Diagram
105
Service Space
108
Glossary
109
Advertisement
Daikin VAM350J8VEB Service Manual (104 pages)
VRV System Air Conditioner
Brand:
Daikin
| Category:
Air Conditioner
| Size: 15.23 MB
Table of Contents
Table of Contents
4
Safety Precautions
6
Meaning of Warnings and Symbols
6
Dangers
7
Warnings
7
Cautions
13
Notices
13
General Operation
14
Troubleshooting
19
To Retrieve Error Codes and Check Error History
19
Via the Indoor Unit Remote Controller BRC1H
19
Error Based Troubleshooting
21
A0-00 - External Protection Device Activated
21
A0-11 - R32 Leakage Detection
22
A1-00 - Main PCB Abnormality
23
A3-00 - Drain Water Level Abnormality
23
A3-08 - Drain Pump Connector Open
24
A6-01-02-05-06 - Fan Motor Abnormality - Motor Lock
25
A6-10-12-14-16 - Fan Motor Abnormality - Overcurrent or IPM Protection
26
A6-11-13-15-17 - Fan Motor Abnormality - Position Detection Error
27
A6-22 - Unstable Fan Rpm
28
A6-28 - Airflow Rate below Critical Threshold
28
A6-29 - Airflow Rate too Low
29
A6-30 - Airflow Rate Lower than Normal
30
A8-01 - Fan Motor Abnormality - Power Supply Abnormality
31
A9-01 - Y1E Expansion Valve Coil Abnormality
31
A9-02 - Y1E Expansion Valve Body Abnormality
32
Drain Back Flow
33
A1P Capacity Setting Error
34
A1P Setting Error for Y1E Expansion Valve
34
C1-00 - Communication Abnormality between Main PCB and Fan PCB
35
C4-00 - Liquid Thermistor Abnormality
36
C5-00 - Gas Thermistor Abnormality
36
C6-01-11-21-31 - Compatibility Error between Main PCB and Fan PCB
37
C6-02-12-22-32 - Setting Error between Main PCB and Fan PCB
37
C6-05-15-25-35 - Fan PCB EEPROM Error
38
C6-06-16-26-36 - Fan PCB Fin Thermistor Malfunction
39
C6-07-17-27-37 - Fan PCB Fin Thermistor Abnormality
40
C9-00 - Air Thermistor Abnormality
40
Discharge Thermistor Abnormality
41
CO2 Sensor Alarm
41
R32 Leak Detection Sensor Failure or Disconnected
42
R32 Leak Detection Sensor Life Time Is Exceeded
43
R32 Leak Detection Sensor Life Time <6 Months
43
R32 Leak Detection Sensor Replacement to Confirm
44
Remote Controller Air Thermistor Abnormality
45
U5-04 - Communication Abnormality between Indoor Unit Main PCB and Remote Controller
45
U5-06 - Supervisor Remote Controller Not Connected/Not Set
47
U8-00 - Transmission Error between Master and Slave Remote Controller
47
U9-01 - Other Indoor Unit Has Error
48
U9-02 - Other Indoor Unit Has Error
48
Wrong Remote Controller
49
Central Address Duplication Error
49
Communication Abnormality with Central Controller
50
Capacity Mismatch between VAM and DX Module
50
Abnormality at VAM Unit
51
Transmission Error between VAM and EKVDX
51
VAM Unit Has A6-28 Error
51
VAM Unit Has A6-29 Error
52
External Protection Device Activated
52
Indoor Air Thermistor Malfunction
53
Indoor Air Thermistor out of Range
53
Outdoor Air Thermistor Malfunction
54
Outdoor Air Thermistor out of Range
54
Low Outdoor Air Temperature
55
00 - Damper Related Malfunction
55
Maintenance
57
Maintenance for Heat Reclaim Ventilation Units
57
Maintenance Safety Precautions
57
Checklist for Maintenance of the Heat Reclaim Ventilation Unit
58
Maintenance of the Air Filter
58
Maintenance of the Heat Exchange Element
60
Maintenance for DX Units
60
Checklist for Yearly Maintenance of the Indoor Unit
60
Cleaning the Air Outlet
61
Maintenance before a Long Stop Period
61
Maintenance after a Long Stop Period
61
Technical Data
62
Detailed Information Setting Mode
62
Detailed Information Setting Mode: Indoor Unit
62
Detailed Information Setting Mode: Remote Controller
62
Wiring Diagram
63
Wiring Diagram: VAM-J8
63
Wiring Diagram: EKVDX
68
Piping Diagram
72
Piping Diagram: Indoor Unit
72
Component Overview
73
Component Overview: DX Unit
73
Component Overview: Heat Reclaim Ventilation Unit
74
Switchbox Overview
77
Field Information Report
79
Service Tools
82
Field Settings
83
To Retrieve the Field Settings
83
Overview of Field Settings for DX Units
88
Overview of Field Settings for Heat Reclaim Ventilation Units
90
Daikin VAM350J8VEB Installation And Operation Manual (32 pages)
Heat reclaim ventilation unit
Brand:
Daikin
| Category:
Fan
| Size: 3.42 MB
Table of Contents
Table of Contents
3
About the Documentation
3
About this Document
3
Specific Installer Safety Instructions
3
For the User
5
User Safety Instructions
5
General
5
Instructions for Safe Operation
6
User Interface
6
Maintenance and Service
6
Maintenance of the Air Filter
6
Maintenance of the Heat Exchange Element
7
Troubleshooting
7
Relocation
8
Disposal
8
For the Installer
9
About the Box
9
Heat Reclaim Ventilation Unit
9
To Remove the Accessories
9
About the Heat Reclaim Ventilation Unit
9
About the EKVDX Option
9
Unit Installation
10
Preparing the Installation Site
10
Installation Site Requirements for the Heat Reclaim Ventilation Unit
10
Preparing the Unit
10
To Install the Optional Adapter PCB
10
To Install the Duct Flanges
11
To Install the EKVDX Option
11
Unit Orientation
11
To Install the Anchor Bolts
12
Duct Connections
12
Electrical Installation
13
Component Electrical Specifications
13
Specifications for Field Supplied Fuses and Wires
14
Opening the Switch Box
14
Electrical Connections for Additional Field Supplied Damper
17
To Connect the Electrical Wiring
17
Configuration
18
To Change Settings
18
Case 1: Change Settings with BRC1E53
18
Case 2: Change Settings with BRC301B61
19
Case 3: Change Settings with BRC1H
19
Field Settings
19
Settings for All Configurations
22
About Setting 19(29)-0-04 and 19(29)-0-05
23
About the Controller
23
BRC1E53 Controller
23
BRC301B61 Controller
24
BRC1H Controller
25
Commissioning
25
Checklist before Commissioning
25
Checklist During Commissioning
26
About the Test Run
26
Troubleshooting
26
Solving Problems Based on Error Codes
26
Error Codes: Overview
26
Disposal
26
Technical Data
27
Wiring Diagram
27
Service Space
28
Advertisement
Advertisement
Related Products
Daikin VAM350HVE
Daikin VAM350HVLT
Daikin VAM350J VEB Series
Daikin VAM300GVJU
Daikin VAM1500J8VEB
Daikin VAM150HVE
Daikin VAM1500HVLT
Daikin VAM1500J VEB Series
Daikin VAM500J VEB Series
Daikin VAM2000HVLT
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL