ABBREVIATIONS / UNITS
Abbreviations
• CBC : Complete Bloodcell Count
• LD
: Lower Discriminator
• LL
: Lower Limit
• PD
: Pre-diluted mode
• QC
: Quality Control
• T1
: T rough Discriminator 1
• T2
: T rough Discriminator 2
• UD
: Upper Discriminator
• UL
: Upper Limit
• WB : Whole Blood mode
Unit
• dL
: deciliter (0.1 liter)
-15
• fL
: femtoliter (10
liter)
-6
• μL
: microliter (10
liter)
-12
• pg
: picogram (10
gram)
Analysis parameters
This instrument provides results for the following parameters:
• WBC : N umber of leukocytes
• RBC : N umber of erythrocytes
• HGB : H emoglobin concentration
• HCT : H ematocrit value: Erythrocyte ratio of total blood volume
• MCV : M ean corpuscular volume
• MCH : M ean corpuscular hemoglobin
• MCHC : Mean corpuscular hemoglobin concentration
• PLT : N umber of platelets
• LYM%/ W-SCR : % of small leukocytes to total WBC
They are assumed to be equivalent to lymphocytes (white cell-small cell ratio).
• MXD%/ W-MCR : % of middle leukocytes to total WBC
They are assumed to be equivalent to monocytes, eosinophils, and basophils
(white cell-middle cell ratio).
• NEUT%/ W-LCR : % of large leukocytes to total WBC
They are assumed to be equivalent to neutrophils (white cell-large cell ratio).
• LYM#/ W-SCC : Absolute number of small leukocytes
They are assumed to be equivalent to lymphocytes (white cell-small cell count).
• MXD #/ W-MCC : Absolute number of middle leukocytes
They are assumed to be equivalent to monocytes, eosinophils, and basophils
(white cell-middle cell count).
• NEUT#/ W-LCC : Absolute number of large leukocytes
They are assumed to be equivalent to neutrophils (white cell-large cell count).
• RDW-SD : Calculated distribution width of erythrocytes, standard deviation
• RDW-CV : Calculated distribution width of erythrocytes, coefficient of variation
• PDW : Calculated distribution width of platelets
• MPV : Mean platelet volume
• P-LCR : Ratio of large platelets (volume exceeding 12 fL) to the total number of
platelets
When analyzing in the pre-diluted mode, only the following eight parameters are
output: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT.
NAMES
i
Sysmex, pocH-100
, pocH-pack 65, pocH-pack 65XL and EIGHTCHECK are registered
trademarks of SYSMEX CORPORATION.
• CELLCLEAN is a trademark of SYSMEX CORPORATION.
• CAPIJECT is a registered trademark of T erumo Corporation.
• ETHERNET is a registered trademark of Xerox Corporation.
• MICROTAINER is a registered trademark of Becton Dickinson Company.
• SARSTEDT, S-MONOVETTE and MICROVETTE are registered trademarks of Walter
Sarstedt Geräte und Verbrauchsmaterial für Medizin und Wissenschaft.
• ISBT128 (International Society of Blood T ransfusion) is copyrighted by and used under
License Agreement with ICCBBA, Inc.
• Linux is a registered trademark or trademark of Linus T orvalds in U.S.A. and other coun-
tries.
All other trademarks not explicitly mentioned in this manual belong to their respective
owners. Sysmex does not authorize their use.
2
i
pocH-100
Revised February 2011

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents