The 210/215 indicators are equipped with software that indicates when an error in the
operation takes place. The following lists the error codes displayed by the 210/215 along with
their meaning. Should you encounter an error code, please refer to this list for the cause.
CALbtn (Calibration button)
CALbtn will be displayed (until the condition changes), on power-up if the calibration switch
is pressed in by the operator, the calibration access screw is the wrong length and is
depressing the switch, the switch is disconnected from the PC board, or the switch is
defective.
CORRECTIVE ACTION: Release the switch. Insure correct screw (#10 x ½ Stainless Steel
fillister head) was installed for the calibration access screw. Referring to Figure No. 6, make
sure calibration switch cable is plugged into P7 on the PC board. Replace calibration switch
assembly. Consult your scale service provider.
ConFiG (Configuration)
2
E
PROM checksum failure. Indicates improper stored calibration data, calibration is
necessary.
CORRECTIVE ACTION: Recalibrate with calibrated test weight.
Error (Error)
An invalid keypad entry was attempted:
A. PRINT key pressed with a negative weight.
B. TARE key pressed to enter a push button tare value of a negative value.
C. ENTER key pressed to enter a tare weight value that exceeds the scale capacity.
D. ENTER key pressed to enter a tare weight value that is inconsistent with the scale
division value (i.e. attempt to enter a tare of 123 with scale divisions of 5).
E. ZERO key pressed when the gross weight is outside the scale zero weight range.
F. lb/kg key pressed to change to kg when the kg tare weight value exceeds 4 digits in
length.
CORRECTIVE ACTION: Determine which of the reasons for the error display is applicable
and take the appropriate corrective action.
ErrAh (Error Analog high)
1. The load cell input is above the range of the indicator.
CORRECTIVE ACTION: Check for improper load cell wiring, excessive load, and for
output of 1 to 40mV.
2. Load cell or circuit failure.
CORRECTIVE ACTION: Consult your scale service provider.
ErrAL (Error Analog Low)
1. The load cell input is below the range of the indicator.
CORRECTIVE ACTION: Check for improper load cell wiring and for output of 1 to 40mV.
2. Load cell or circuit failure.
CORRECTIVE ACTION: Consult your scale service provider.
Err1 (Error 1)
A program checksum mismatch has been detected.
CORRECTIVE ACTION: Consult your scale service provider.
Err3 (Error 3)
Internal RAM failure.
CORRECTIVE ACTION: Consult your scale service provider.