Error Codes

The Model 200 Weight Indicator is equipped with software that indicates when an error in the
operation takes place. The following lists the error codes displayed by the indicator along with
their meaning. Should you encounter an error code, please refer to this list for the cause.
CALbtn (Calibration button)
CALbtn will be displayed (until the condition changes), on power-up if the calibration switch
is pressed in by the operator or the switch is defective.
CORRECTIVE ACTION: Release the switch. Replace calibration switch assembly.
Consult your scale service provider.
ConFiG (Configuration)
2
E
PROM checksum failure. Indicates improper stored calibration data, calibration is
necessary.
CORRECTIVE ACTION: Recalibrate with calibrated test weight.
Error (Error)
An invalid keypad entry was attempted:
A. PRINT key pressed with a negative weight.
B. TARE/ENTER key pressed to enter a push button tare value of a negative value.
C. TARE/ENTER key pressed to enter a tare weight value that exceeds the scale capacity.
D. TARE/ENTER key pressed to enter a tare weight value that is inconsistent with the scale
division value (i.e. attempt to enter a tare of 123 with scale divisions of 5).
E. ZERO key pressed when the gross weight is outside the scale zero weight range.
F. UNITS/TEST key pressed to change to kg when the kg tare weight value exceeds 4
digits in length.
CORRECTIVE ACTION: Determine which of the reasons for the error display is applicable
and take the appropriate corrective action.
ErrAh (Error Analog high)
1. The load cell input is above the range of the indicator.
CORRECTIVE ACTION: Check for improper load cell wiring, excessive load, and for
output of 1 to 40mV.
2. Load cell or circuit failure.
CORRECTIVE ACTION: Consult your scale service provider.
ErrAL (Error Analog Low)
1. The load cell input is below the range of the indicator.
CORRECTIVE ACTION: Check for improper load cell wiring and for output of 1 to 40mV.
2. Load cell or circuit failure.
CORRECTIVE ACTION: Consult your scale service provider.