SETUP AND CALIBRATION, CONT.
A oFF= (Auto Shutoff)
The Automatic Shutoff feature will automatically turn the indicator off (when it is not in use)
after a predetermined period of inactivity to prolong battery life. To turn the indicator back on
you must press the ON / OFF key.
Press the ENTER key to show the current status for this feature. A number other than 0
indicates that the auto shutoff feature is enabled and the displayed number corresponds to the
number of minutes of stable weight displayed before the indicator is turned off automatically.
Note that a 0 indicates the feature has been turned off. If the setting displayed is acceptable,
press the ENTER key again to save it. Otherwise, use the numeric keys to enter a new value
(0 to 10) then press the ENTER key to store the new setting.
CLtAr= (Clear Tare)
The Clear Tare feature allows the indicator to clear the Stored Tare weight when the Net
weight goes below a value greater than 1/2 the stored tare weight or goes below zero (a
negative net weight after display of a positive net weight). With this feature enabled, the
operator must re-set the tare after completion of a transaction when the load (container plus
item) is removed from the scale.
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys, 0/NO or 1/YES, enter the
new setting, then press the ENTER key to save it.
CLtAr=1 (Yes)
Automatically clears Stored Tare
when Net weight goes below zero
id= (ID Prompt)
The id= (ID=) prompt enables an ID prompt before printing a ticket.
With the display showing id=, press the ENTER key to show the current value. If the setting
displayed is acceptable, press the ENTER key again to save it. Otherwise, using the numeric
keys, 0/NO or 1/YES, enter the new setting, then press the ENTER key to save it.
id=1 (Yes)
id= will be displayed when PRINT key
is pressed and printed on the ticket.
If you selected id=1 (Yes, ID Prompt), an additional prompt, "a clr=" will be displayed.
If you selected id=0 (No ID Prompt) proceed to A-d (A-d?) Analog to Digital Filtering.
A cLr= (Auto Clear ID)
The a clr= (Auto Clear ID) prompt determines whether the ID is automatically cleared after
printing the ticket. Note that it is only displayed when id= YES is selected.
With the display showing a clr=, press the ENTER key to show the current value. If the
setting displayed is acceptable, press the ENTER key again to save it. Otherwise, using the
numeric keys, 0/NO or 1/YES, enter the new setting, then press the ENTER key to save it.
A clr=1 (Yes)
Automatically clears the ID after the
ticket has printed.
8200-M411-O1 Rev D  210/215 Installation & Technical
CLtAr=0 (No)
Stored Tare is not cleared when
Net weight goes below zero
id=0 (No)
Normal print operation (no ID prompt)
will occur.
a clr=0 (No)
ID is not cleared when ticket prints
and can be used for next transaction.