Cardinal 210 Installation And Technical Manual page 64

Table of Contents

Advertisement

This addendum is to inform you of the TEST MODE feature in the 200, 205, 210 and 215 Weight Indicators.
This addendum should be used in addition to the Installation and Technical manual for your indicator.
NOTE! On the 200 and 205, the functions of numeric keys are replaced by using UNITS/LEFT ARROW
and ASTERISK/UP ARROW keys. The cursor location is identified by the blinking character and can be
advanced to the left to the next position by pressing the UNITS/LEFT ARROW key. Pressing the
ASTERISK/UP ARROW key will change the blinking character to the next value.
To Start Test Mode
1. Remove calibration access screw.
2. Press ON/OFF key to turn indicator ON.
3. Insert a small screwdriver or other tool into the access hole and press the CAL switch.
4. Display will change to SETUP.
5. Press UNITS/TEST key.
6. Display will change to tESt=.
7. Press ENTER key to show current test function value (which will be 0, test feature off).
8. Using the numeric keys, enter test function value and then press ENTER key.
4 = raw A/D readings
16 = display milliVolts
9. Display will change to SETUP.
10. Press
(ASTERISK) key to begin test.
11. Display will change to show test data.
To Change Test Mode
1. With indicator displaying test data, insert a small screwdriver or other tool into the access hole and
press the CAL switch.
2. Display will change to SETUP.
3. Press UNITS/TEST key.
4. Display will change to tESt=.
5. Press ENTER key to show current test function value.
6. Using the numeric keys, enter test function value and then press ENTER key.
4 = raw A/D readings
16 = display milliVolts
7. Display will change to SETUP.
8. Press
(ASTERISK) key to begin test.
9. Display will change to show test data.
To Stop Test Mode
1. With indicator displaying test data, insert a small screwdriver or other tool into the access hole and
press the CAL switch.
2. Display will change to SETUP.
3. Press UNITS/TEST key.
4. Display will change to tESt=.
5. Press ENTER key to show current test function value.
6. Press numeric 0 key (0 = test feature off) and then press ENTER key.
7. Display will change to SETUP.
8. Press
(ASTERISK) key to stop test and reset indicator.
9. The indicator is now ready for normal operation.
IMPORTANT! Once TEST MODE has been enabled, the indicator will power on with TEST on
the display. Operator must press ENTER key to stay in test mode or press
to disable test mode.
ADDENDUM FOR MANUALS:
8200-M035-O1 Rev B 10/09, 8200-M024-O1 Rev G 10/09, 8200-M411-O1 Rev C 10/09
01/10
Addendum to the
200, 205, 210 and 215
Installation and Technical Manual
TEST MODE
(ASTERISK) key

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

215210dc215dc210-fe

Table of Contents