Error Codes - Cardinal 748 Technical/Operation Manual

Weight indicating instrument
Table of Contents

Advertisement

Inbound - empty or loaded
SCALE
Outbound - empty or loaded
SCALE
NOTE! Regardless of whether the truck to be processed has a temporary or permanent
ID number, it is processed in the same manner: Press ID, key-in ID number, press PRINT.
The 748 is equipped with software that indicates when an error in the operation takes place. The
following lists the error code displays supported by the 748 along with their meaning. Should you
encounter an error display, please refer to this list for the cause.
UnStb
UnLod
LoAd
oF
oL
CALb
PERMANENT ID NUMBER USE
Step 1- Enter truck permanent ID and tare weight.
Press F1
Enter ID number to be assigned
Press ENTER - display shows Sto=
Press ENTER to display value stored in memory
or scale weight
Press GROSS to enter the scale weight or key-in value
Press ENTER - display shows ACC=
Press ENTER to show accumulator
Press ENTER to save or CLEAR to reset and press
ENTER
Repeat step 1 for all permanent trucks.
Step 2 - Process trucks as required.
Truck pulls on scale
Press ID
Enter ID number assigned to truck (see step 1)
Press PRINT
Printer records gross, tare, net and accumulated new
weights and ID number

ERROR CODES

Motion is present when trying to power up, print, zero or perform a
push button tare function. CORRECTIVE ACTION: wait for a stable
weight display ( STABLE annunciator on) before performing any of
these operations.
The weight on the scale exceeds the zero range when powering up.
CORRECTIVE ACTION: remove the excess load then press the
ON/ZERO key.
The scale deadload is less than the zero range when powering up.
CORRECTIVE ACTION: replace the scale platform or items
normally on the scale then press the ON/ZERO key.
The 748 is attempting to display a positive number greater than six
(6) digits in length or a negative number of more than five (5) digits.
CORRECTIVE ACTION: return to Gross Weight mode and review
Tare value. May indicate miscalibration.
The load on the scale exceeds the scale capacity plus nine (9)
divisions. CORRECTIVE ACTION: remove the over capacity load
from the scale platform. May indicate miscalibration.
EEPROM checksum failure. CORRECTIVE ACTION: recalibrate
with "C" numbers or weight.
38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents