SETUP AND CALIBRATION, CONT.
LFt= (Legal For Trade)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys, 0/NO or 1/YES, enter the
new setting, then press the ENTER key to save it.
LFt=1
Interval Settings (Int=) allowed
are: 1, 2, 5, 10 , 20, 50
NOTE! When both
Scale must have between 100 and 10,000 divisions
Tra = .5 or 0 to 3
Inhibit serial data during input
Disables COUNT key
Date = mm/dd/yy
Trl = no
Cap + 4% to OC
LFt=1
NOTE! When
Uns = 1
Date = dd/mm/yy
Trl = yes
Cap + 9 grads to OC
PT printed with tare
Lamp test on power up
Unit1= (Weighing Unit 1)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys enter the new setting,
then press the ENTER key to save it. Allowable values are:
0 = none
1= tn (tons) – Only on 210
2= g (grams)
3 = lb (pounds)
int= (Interval Setting)
Press the ENTER key to show the current value.
If LFt = 1 (Legal For Trade = YES), using the numeric keys enter the new setting, then
press the ENTER key to save it. Allowable values are: 1, 2, 5, 10, 20 or 50.
If LFt=0 (Legal For Trade = NO), using the numeric keys enter the new setting, then press
the ENTER key to save it. Allowable values are: 1 through 99.
In either case, if the setting displayed is acceptable, press the ENTER key again it.
dPP= (Decimal Point Setting)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys enter the new setting,
then press the ENTER key to save it. Allowable values are: 0, 1, 2 or 3.
0 = XXXXXX
1= XXXXX.X
8200-M411-O1 Rev D  210/215 Installation & Technical
22
LFt=0
Interval Setting (Int=) is
selectable from 1 to 99.
LFt=1
USA=1
and
, the followings results occur:
USA=0
and
, the followings results occur:
4 = oz (ounces)
5 = kg (kilograms)
6 = tonnes (metric tons) – Only on 210
7 = lb/oz (pounds/ounces)
2 = XXXX.XX
3 = XXX.XXX