Cardinal 210 Installation And Technical Manual page 20

Table of Contents

Advertisement

The 210/215 includes support for visual tickets. Visual
tickets are designed by the PC based programs Visual
Print or nControl, then downloaded to the indicator.
Two programmable formats in addition to the standard
print tab settings are allowed.
Print formats are selected by using the ASTERISK and
PRINT keys in combination (refer to the next section
for details). NOTE! When the PRINT key is pressed,
the indicator looks for the selected format. If a visual
ticket is not found it reverts to the print tab settings.
ZERO/REVIEW KEY
This key performs two functions. In normal operation, pressing this key will cause an
immediate zeroing of the weight display up to the selected limit of 4% or 100% of the scale's
capacity. Note that this selection is made during the setup and calibration of the indicator.
Pressing this key after the ASTERISK key will enter the Review mode of Setup and
Calibration. Refer to description of ASTERISK key and the Setup Review section of this
manual for details.
TARE KEY (with diamond "T" symbol)
This is a dual function key. Pressing the TARE key alone (Pushbutton Tare mode) will store
the current gross weight as a new tare weight and cause the weight display to change to the
net weight display mode (Net annunciator turns on). Pressing it key after entering a numeric
value (Keypad Tare) will cause the value entered to be accepted as a new tare weight.
NOTE! Tare weights equal to or greater than scale capacity cannot be entered. In addition,
keypad tare weight division value must be same as scale division value. For example, a
unit with .005 lb as division value will display Error if you enter 1.003 for tare weight.
NET/GROSS KEY
This key is used to toggle between Net and Gross weight modes. The selected mode is
indicated by turning on the appropriate annunciator on the display. Note that if no valid tare
weight has been entered, pressing this key will cause a momentary "notArE" display error and
the indicator will remain in the Gross weight mode.
TARE KEY (with weight "T"symbol)
Pressing this key will display the current tare weight for three seconds.
UNITS/TEST KEY
This key performs two functions. In normal operation, it is used to select the units in which the
weight is to be displayed. The available units of measure ("unit1" and "unit2") are enabled or
disabled in setup. The available units include tons, pounds only, pound-ounces, ounces only,
tonnes (metric tons), kilograms, and grams. Note that not all combinations are supported.
Pressing this key after the ASTERISK key will enter the Test mode. The Test mode is used to
conduct a test of all display elements. Refer to description of ASTERISK key for details.
0 THROUGH 9 KEYS
These keys are used to enter numeric data during the setup and calibration as well as during
normal operation of the indicator. NOTE: The 1 and 0 keys have dual functions. They are
used to enter numeric data during setup and calibration as well as during normal operations
and are also used to answer yes (1 = YES) or no (0 = NO) to various prompts.
ENTER KEY
This key serves two purposes. First, when reviewing setup parameters, pressing the ENTER
key will display the current setting of the parameter. Second, the ENTER key is used to signal
completion of the entry of data and causes the indicator to process the data entered.
8200-M411-O1 Rev D  210/215 Installation & Technical
16
KEYPAD FUNCTIONS, CONT.
#2
10:19 08/23/2009
100.00 lb G
20.00 lb T
80.00 lb N
0.00 lb GROSS ACCUM
272.00 lb NET ACCUM
TICKET EXAMPLE