Cardinal 210 Installation And Technical Manual page 27

Table of Contents

Advertisement

SETUP AND CALIBRATION, CONT.
CAP= (Capacity)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys enter the new setting,
then press the ENTER key to save it. Allowable values are: 1 through 999,999.
NOTE! Capacity cannot exceed 999,999.
Unit2= (Weighing Unit 2)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys enter the new setting,
then press the ENTER key to save it. Allowable values are:
0 = none
1= tn (tons) – Only on 210
2= g (grams)
3 = lb (pounds)
NOTE! The selection for Unit2 cannot be the same as Unit1. In addition,
dependent upon the selection for Unit1 and the interval and decimal point settings,
not all unit combinations are available.
trA= (Zero Tracking Range)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys enter the new setting,
then press the ENTER key to save it. Allowable values are: 0 (disables Zero Tracking), .5, or 1
through 9.
trL= (4% Zero Range)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys, 0/NO or 1/YES, enter the
new setting, then press the ENTER key to save it.
trL=1 (Yes)
4% of scale capacity
PUO= (Power-Up Zero Feature)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys, 0/NO or 1/YES, enter the
new setting, then press the ENTER key to save it.
PUO=1 (Yes)
Automatic Re-Zero on Power-Up
td = (12 or 24 Time Format)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, use the numeric keys to select the format (12 or
24 hour) of the Model 210 clock operation, then press the ENTER key to save it. Note that in
the 24 hour format, 12 is added to all times after noon, i.e. 3 PM would be 1500.
td = 12
12 hour clock (3PM displays 3:00)
8200-M411-O1 Rev D  210/215 Installation & Technical
4 = oz (ounces)
5 = kg (kilograms)
6 = tonnes (metric tons) – Only on 210
7 = lb/oz (pounds/ounces)
trL=0 (No)
Full capacity (no limit)
PUO=0 (No)
No Re-Zero on Power-Up
td = 24
24 hour clock (3PM displays 15:00)
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

215210dc215dc210-fe

Table of Contents