SETUP AND CALIBRATION, CONT.
d oUt = X, Y (Digital Output)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, use the numeric keys to select the X, Y values for
the digital output, then press the ENTER key to save it.
d out = X, Y
where:
X = State below cutoff (0 = LOW, 1 = High)
Y = Preset Number or Checkweigher Mode
0 = Digital Output is disabled
1 = Low State before cutoff with 1 active Preset
2 = Low State before cutoff with 2 active Presets
3 = Low State before cutoff with 3 active Presets
11 = High state before cutoff with 1 active Preset
12 = High state before cutoff with 2 active Presets
13 = High state before cutoff with 3 active Presets
4 = Low State before cutoff on Checkweigher Mode
14 = High state before cutoff on Checkweigher Mode
5 = Axle Weigher Operation Mode
P-bAL= (Preset Print-On-Balance)
With only one Preset selected (d OUt=1 or 11), an additional prompt P-bAL= (automatic
Print on Balance) will be displayed. If selected (P-bAL=YES), when the weight is above or
equals the preset value and all motion stops, weight will be printed (if a printer is attached).
Note that the weight must go below 50% of the preset value before another print operation can
be performed.
If the setting displayed is acceptable, press the ENTER key to save it. Otherwise, using the
numeric keys, 0/NO or 1/YES, enter the new setting, then press the ENTER key to save it.
P-bAL=1 (Yes)
Automatic Print on Balance Enabled
P-bAL= (Checkweigher Print-On-Accept)
With Checkweigher selected (dOUt= 4 or 14), an additional prompt P bAL, Print on Balance,
(automatic print on accept) will be displayed. If selected (P-bAL=YES), when the scale weight
is stable and in the accept range of the checkweigher, the weight will be printed (if a printer is
attached).
If the setting displayed is acceptable, press the ENTER key to save it. Otherwise, using the
numeric keys, 0/NO or 1/YES, enter the new setting, then press the ENTER key to save it.
P-bAL=1 (Yes)
Automatic Print on Accept Enabled
SLEEP= (Sleep Mode Feature)
The Sleep Mode feature conserves battery power when the indicator remains unused for a
selected period of time. With the feature enabled, the load cell excitation will be reduced and
the display will be blank. NOTE! The sleep mode only functions on the 215, when the
indicator is powered by the NiMH batteries and not by AC power.
Press the ENTER key to show the current status of this feature. If a number other than 0 is
shown, this feature is selected and the number shown corresponds to the number of minutes
of a stable zero weight reading before the indicator enters the sleep mode. If the setting
displayed is acceptable, press the ENTER key again to save it. Otherwise, use the numeric
keys to enter a new value (0 to 10) then press the ENTER key to store the new setting. Note
that entry of a 0 disables this feature.
8200-M411-O1 Rev D  210/215 Installation & Technical
24
P-bAL=0 (No)
Automatic Print on Balance Disabled
P-bAL=0 (No)
Automatic Print on Accept Disabled