Ivu Output Waveforms - Banner iVu Plus BCR Gen2 Series Instruction Manual

Hide thumbs Also See for iVu Plus BCR Gen2 Series:
Table of Contents

Advertisement

Note:
Table 5: Required iVu Input Signal Voltage
NPN
Note: If the device used to trigger or remote teach the iVu BCR is a sinking device, these are the options
regarding the use of a pull-up resistor:
Option 1: Put a pull-up resistor, rated approximately 1 kΩ, between the device's positive (+) voltage and
the device's input as shown below.
Option 2: Enable the Input Pullup. Go to iVu BCR Main Menu > System > Discrete I/O > Input Pullup.

11.10.3 iVu Output Waveforms

Function
Ready
Outputs 1,2, and 3
(Set as Active Pass)
Outputs 1, 2, and 3
(Set as Active Fail)
Strobe Out
(Configure as External
& Expose Based)
ON
< 2 V dc
Sinking
VCC
1k ohm
Pullup Resistor
NPN
(Pass)
(Pass)
Figure 52. PNP Outputs
www.bannerengineering.com - Tel: + 1 888 373 6767
iVu Plus BCR Gen2 Series Sensor
OFF
+10 V dc to 30 V dc
iVu
Trigger Input
Remote Teach Input
(Fail)
(Pass)
(Pass)
(Fail)
65