5 Additional Remote TEACH Procedures

5.1 TEACH Analog Output and Discrete Output Switch Points Together

Use the following procedure to teach identical Analog Output and Discrete Output switch points at the same time using the
remote input. This feature is not available using the buttons.
1. Access the TEACH mode.
Action
Single-pulse the remote input.
2. Present the target.
Action
Present the switch point one target.
3. TEACH the sensor.
Action
Three-pulse the remote input.
4. Present the target.
Action
Present the switch point two target.
5. TEACH the sensor.
Action
Single-pulse the remote input.

5.2 TEACH Analog Output and Discrete Output Midpoints Together

Use the following procedure to teach an identical Analog Output 12 mA (5 V) point and Discrete Output midpoint (switch
point) at the same time using the remote input. This feature is not available using the buttons. Note that if the window sizes
were set independently (using the buttons), the windows taught using the following procedure could be different.
1. Access the TEACH mode.
L-GAGE
T
T
T
www.bannerengineering.com - Tel: 763.544.3164
®
LE250/550 Analog/Discrete Laser Gauging Sensors
Result
"RMT TCH" and the current measurement
value display.
Result
"RMT TCH"and the target's measurement
value display.
Result
"TchA&D1 Teaching" displays while the
sensor is being taught.
TEACH Accepted
T
T
The new value displays on the second line
of the display, flashes, and then "TchA&D2"
T
and the current measurement value display.
TEACH Not Accepted
"FAIL" flashes, the sensor returns to step 2,
and "RMT TCH" displays.
Result
"TchA&D2" and the target's measurement
value display.
Result
"TchA&D2 Teaching" displays while the
sensor is being taught.
TEACH Accepted
The new value displays on the second line
T
of the display, flashes, and the sensor
returns to Run mode.
TEACH Not Accepted
"FAIL" flashes, the sensor returns to step 2,
and "RMT TCH" displays.