14.4.3 Input and Output Flags Bits

The Input Bits are used to command execution of basic functions. The Output Bits are used to push single bit outputs from
the iVu BCR device to the PLC. The 32 bits of iVu BCR output can also be accessed using the bits of the first two Output
Registers (Input Bits ACK Register(word 0) and Output Bits Register (word1)).
Table 10: Inputs Bits Register (Command Flag Bits)
Bit Position
15
14
13
12
Command
Table 11: Input Bits ACK Register (ACK Flag Bits)
Bit Position
15
14
13
12
Command
ACK
Table 12: Output Bits Register (iVu BCR Status Flag Bits)
Bit Position
15
14
13
12
Execution
System
Teach
Missed
Error
Error
Error
Trigger

14.4.4 Configuration Assembly Object

The iVu BCR EtherNet/IP implementation does not support an assembly object Configuration instance. However, one is
required for the creation of implicit Class 1 connections on a ControlLogix
is defined as instance number 128 (0×80). Its size is zero.

14.4.5 Data Formats

The iVu BCR EtherNet/IP implementation supports 32-bit Integers in LSW_MSW data format. The LSW_MSW data format is
such that the least significant word is stored first, then the most significant word. This format is used for Allen-Bradley
ControlLogix PLCs.
The string format is compatible with the Allen-Bradley ControlLogix built-in string data type. This format is a 32-bit (DINT)
length followed by character bytes (SINT). This results in the following string format as viewed from the iVu BCR:
0
Word
Length
Length
LSW
MSW

14.4.6 Minimum Requested Packet Interval (RPI) Value

The iVu BCR can operate with input and output Requested Packet Intervals (RPIs) as low as 50 milliseconds. The device
may not operate reliably if a lower RPI value is selected.
11
®
ControlLogix
is a trademark of Rockwell Automation, Inc.
106
11
10
9
11
10
9
11
10
9
1
2
byte 1
byte 0
www.bannerengineering.com - Tel: + 1 888 373 6767
8
7
6
5
Set BCR
Set BCR
Mask
String
8
7
6
5
Set BCR
Set BCR
Mask
String
ACK
ACK
8
7
6
5
Output 3
Output 2
Output 1
®
11
family PLC. Therefore, a configuration instance
3
byte 3
byte 2
byte 5
4
3
2
1
Gated
Teach
Trigger
Trigger
Latch
4
3
2
1
Gated
Teach
Trigger
Trigger
Latch
ACK
ACK
ACK
4
3
2
1
Ready to
Read/No
Pass/Fail
Latch
Read
4
byte 4
...
0
Product
Change
0
Product
Change
ACK
0
Ready
...