14 Industrial Ethernet Overview

14.1 Device Setup

14.1.1 Set IP Address

When shipped, the device is assigned a default IP address of 192.168.0.1, a default Subnet Mask of 255.255.255.0, and a
default Gateway of 0.0.0.0. To change these defaults, go to Main Menu > System > Communications > Ethernet I/O.
14.1.2 Set the Industrial Ethernet Protocol (Ethernet/IP
PCCC/PROFINET
The Industrial Ethernet communication channel is disabled by default. To enable this channel, go to Main Menu > System >
Communications > Industrial Ethernet > Connection. Select the desired channel: Ethernet/IP, MODBUS, PCCC, or
PROFINET. Only one type of connection can be established at a time.
View information about an established connection from Main Menu > System > Communications > Industrial Ethernet >
Status. Click the desired connection to view details.
This device provides extensive logging for the communication that occurs over the Industrial Ethernet connection. View logs
from either Main Menu > System > Communications > Industrial Ethernet > View Logs or Main Menu > Logs >
Communication Logs > Industrial Ethernet.

14.1.3 Set Trigger Mode

Trigger the iVu BCR using the hardware trigger input line or an internally supplied software trigger, or by toggling a bit over
Industrial Ethernet. To only accept triggers generated through the Industrial Ethernet communication channel, go to Main
Menu > Imager > Trigger, and select Industrial Ethernet Only from the drop-down list.

14.2 Supported Functions

Control the iVu BCR over EtherNet/IP, PCCC, Modbus/TCP, or PROFINET using the input and output data the iVu BCR
makes available as a slave device for those protocols.
The following are some of the device operations that can be performed using input and output values:
Product Change
Teach Enable
Trigger the iVu BCR
Read output indicators (pass, fail, ready, error)
Read counters (pass, fail, system error, missed trigger, frame count, iteration count)
Read sensor results

14.2.1 iVu BCR Input Values

The operation of the iVu BCR can be controlled through input bits and commands.
Register/Input Coil Bits
The following commands can only be executed using bits:
Input Coil Bit
Command
0
Product Change
1
Teach Latch
2
Trigger
3
Gated Trigger
5
Set BCR String
6
Set BCR Mask
®
)
Description
Execute a product change (inspection number specified in the "Product Change
Number" 32-bit integer register)
Latch a teach flag. The Teach is executed on the next trigger
Causes the iVu BCR to run the current inspection
Causes the iVu BCR to start looking for requested barcodes
Sets the barcode compare string
Sets masks for the barcode compare string
www.bannerengineering.com - Tel: + 1 888 373 6767
iVu Plus BCR Gen2 Series Sensor
/Modbus/
99