Display Icons; Communications Log Icons - Banner iVu Plus BCR Gen2 Series Instruction Manual

Hide thumbs Also See for iVu Plus BCR Gen2 Series:
Table of Contents

Advertisement

iVu Plus BCR Gen2 Series Sensor

8.1.2 Display Icons

Icon
Description
The Inspection Passed icon is located in the upper-left of the display. This icon indicates that the last
inspection passed the test conditions.
One of the possible Inspection Failed icons located in the upper-left of the display. This icon indicates that
the last inspection failed.
In External - Single or External Gated trigger mode, this is one of the possible Inspection Failed icons in the
upper-left of the display. This icon indicates that the inspection failed because there were fewer barcodes
than specified by the Barcode Count.
In Continuous Scan mode this icon is in the upper-left of the display. This icon indicates that the sensor is
still scanning the captured image and hasn't yet found the number of barcodes specified by the Barcode
Count.
In External - Single trigger mode, this is one of the possible Inspection Failed icons in the upper-left of the
display. This icon indicates that the inspection failed because the inspection timed out based on the Scan
Time Limit value.
In Continuous Scan or External - Gated trigger mode, this icon, in the upper-left of the display, indicates a
busy timeout. That is, the scan timed out based on the Scan Time Limit, but the outputs are not affected.
One of the possible Inspection Failed icons in the upper-left of the display. This icon indicates that the
sensor is in fail hold mode.
One of the possible Inspection Failed icons in the upper-left of the display. This icon indicates that the data
compare has failed for the barcode that the sensor read.
The Device Locked icon is located in the upper-left of the display. This icon indicates that the device is in a
locked state. If no icon is displayed, the device is unlocked.

8.1.3 Communications Log Icons

Icon
Description
Port open.
Port closed.
Indicates that the command has been processed without errors.
Indicates that the incoming entry is stalled (no new bytes), or end-of-frame delimiter was not received, or
client is not reading data on Ethernet.
Indicates whether the response frame contains an error or is dropped, the log entry icons for the request
and the response frames are red, and the displayed error count increments by one.
If the command takes a long time to process, the last long entry changes to an hourglass (for example,
during trigger of long inspections).
38
www.bannerengineering.com - Tel: + 1 888 373 6767

Advertisement

Table of Contents
loading

Table of Contents