14.9 Command Channel Command Status Register

The command status register will confirm receipt of a command by reflecting the exact command ID received, regardless of
whether the command was valid or not.

14.10 Diagnostic Guide

iVu BCR devices provide several methods to help diagnose communication issues when using Ethernet communications.

14.10.1 Ethernet Diagnostics

To verify Ethernet connectivity, follow these steps:
1. Verify that all of the cables are connected and properly seated.
2. Examine the Ethernet I/O LED located on the top of the iVu BCR, between the Pass/Fail and System Status LEDs.
The light should be either on or blinking.
3. Go to System > Logs > System Log.
4. Verify that the log entry indicates that the Ethernet link is up:
168
Gated Trigger
0
1
X
Set
GatedTrigger
= 1
GatedTriggerACK
Verify :
= '1 '
Read Results
= 0
Figure 175. Gated Trigger Timing Diagram