Remote Teach - Banner iVu Plus BCR Gen2 Series Instruction Manual

Hide thumbs Also See for iVu Plus BCR Gen2 Series:
Table of Contents

Advertisement

iVu Plus BCR Gen2 Series Sensor
For all subsequent triggers, when the sensor reads the barcode data, it compares it against this reference data.

6.3.1 Remote Teach

The Remote Teach function is a method of remotely updating inspection parameters while the iVu BCR is running. The
sequence of events for executing a Remote Teach are:
1. With the device Ready (see
2. The iVu BCR recognizes that the Remote Teach line has been pulsed and waits for the next valid trigger.
3. At the next valid trigger, Ready goes inactive (the Green Ready LED shuts OFF), and the iVu BCR acquires a new
image.
When a Remote Teach occurs, the data of the first read barcode is saved as Data Compare input. Inspections executed on
the next trigger use the new data for comparison with subsequently read barcodes. If the previous input data contained any
masked characters, Remote Teach retains the masked characters only if the new data is of the same length as the previous
input data. If the length does not match, masking is removed.
32
Installation Instructions
(p. 18)), pulse the Remote Teach line.
www.bannerengineering.com - Tel: + 1 888 373 6767