568
The ICP Test Kit is used to check ICP system
diagnostics. The ICP adapter is used with an ICP
sensor and the VC Gasket Breakout Harness to check
the integrity of the high-pressure pump and IPR. The
fitting is adapted to an air line to pressurize the UVC
components and check for leaks.

Inline Shut-off Valve

Figure 544 Part No. 221406
The Inline Shut-off Valve is used to make a test line
assembly that connects to the ICP system test adapter
to check for aerated oil specifically at the EOT sensor
port. The shut-off valve can also be used to make a
test line assembly to check for aerated fuel.
Read all safety instructions in the "Safety Information" section of this manual before doing any procedures.
8 DIAGNOSTIC TOOLS AND ACCESSORIES
EGES-270-1
Follow all warnings, cautions, and notes.
© August 2008 Navistar, Inc.

Vacuum Pump and Gauge

Figure 545 ZTSE2499
The Vacuum Pump and Gauge is used to test the
operation of the fuel pump.

Charge Air Cooler Test Kit

Figure 546 ZTSE4341
The Charge Air Cooler (CAC) Test Kit is used to
pressurize the charge air cooler and piping to check
for leaks.