6. Run engine at low idle, measure ICP signal
voltage, and record on Diagnostic Form.
If ICP is high or unstable for low or high idle,
do step 8.
If ICP is in specification, continue with Test 11
Injector Disable.
7. Run engine at high idle, monitor ICP, and record
initial results on Diagnostic Form. Continue to
run the engine at high idle for 2 minutes, monitor
ICP, and record the 2 minute results on Diagnostic
Form. Compare the two ICP readings. ICP that
rises above the specification at any point during
the two minutes, indicates oil aeration.
If ICP is high or unstable for low or high idle,
do step 8.
If ICP is in specification, continue with Test 11
Injector Disable.
WARNING: To avoid serious personal injury,
possible death or damage to the engine or vehicle
– comply with the following when taking oil
sample:
When routing oil line, do not run the line too
close to moving parts.
Do not let the line touch hot engine surfaces.
Oil is hot. Use protective gloves when taking
oil sample. Use caution handling oil sample to
avoid spilling.
WARNING: To avoid serious personal injury
or possible death, do not allow engine fluids to
stay on your skin.
Clean your skin and nails
with soap and water, or a good hand cleaner.
Wash or properly throw away clothing or rags
containing engine fluids. Engine fluids contain
certain elements that may be unhealthy for skin
and could even cause cancer.
NOTE: Engine fluids, oil, fuel, and coolant, can be a
threat to the environment. Never dispose of engine
fluids by putting them in the trash, pouring them on the
ground, in the sewers, in streams or bodies of water.
Collect and dispose of engine fluids according to local
regulations.
8. Turn off engine.
Read all safety instructions in the "Safety Information" section of this manual before doing any procedures.
6 PERFORMANCE DIAGNOSTICS
9. Use the ICP system test adapter and inline
Figure 312 Test hose assembly
10. Remove EOT sensor from EOT port. Oil will spill
11. Run engine at high idle for 2 minutes.
12. Return engine to low idle, take oil sample, and
13. Record results on Diagnostic Form.
EGES-270-1
Follow all warnings, cautions, and notes.
© August 2008 Navistar, Inc.
shut-off valve to make a test line assembly to
take oil sample.
NOTE: The mechanic is expected to keep the
test line for future diagnostics. Expense the test
line as an essential tool and keep it with other
diagnostic tools. Warranty will not cover the cost
of the test line.
1.
Inline shut-off valve
2.
ICP system test adapter
3.
Oil sample line
out. Quickly install test hose assembly and
capture oil sample in clear container.
check for aerated oil.
If oil is aerated, a large quantity of air bubbles
mixed throughout the oil, or foam build up on
top of the oil will be seen. Correct condition.
If oil is not aerated, disconnect ICP sensor
and check engine stability.
corrected, see "ICP Operational Voltage
Checks" – Section 7 (page 457).
If ICP is still high or unstable, and engine has
optional engine brake, continue to "Monitoring
BCP using VC Gasket Breakout Harness."
If problem is