Navistar International DT 466 Diagnostic/Troubleshooting Manual page 228

Hide thumbs Also See for International DT 466:
Table of Contents

Advertisement

224
Figure 288 Fuel Pressure Gauge
1.
Quick disconnect check valve
2.
Fuel test line
3.
Fuel Pressure Gauge
4.
Inline shut-off valve
5.
Clear test line
Figure 289 Fuel Pressure Test Adapter
NOTE: If the engine is equipped with a Shrader valve,
use the Fuel Pressure Test Adapter.
Read all safety instructions in the "Safety Information" section of this manual before doing any procedures.
6 PERFORMANCE DIAGNOSTICS
Figure 290 Fuel/Oil Pressure Test Coupler
NOTE: If the engine is equipped with a diagnostic
coupling, adapt the Fuel/Oil Pressure Test Coupler to
the Fuel Pressure Gauge.
Figure 291 Fuel Pressure Gauge to fuel pressure
test adapter
2. Connect Fuel Pressure Gauge with shut-off valve
3. Route the clear hose into a drain pan.
EGES-270-1
Follow all warnings, cautions, and notes.
© August 2008 Navistar, Inc.
and clear 3/8" diameter hose to test valve.
WARNING: To avoid serious personal
injury, possible death or damage to the engine
or vehicle – comply with the following:
When routing test line, do not crimp the line,
run the line too close to moving parts, or let
the line touch hot engine surfaces.

Advertisement

Table of Contents
loading

This manual is also suitable for:

International dt 570International ht 570

Table of Contents

Save PDF