8. After replacing the filter cartridge, add engine oil through oil
filler port (F) until the oil level is between H and L marks on the
dipstick.
9. Run the engine at idle for a short time, then stop the engine,
and check that the oil level is between H and L marks on the
dipstick. For details, see "CHECK OIL LEVEL IN ENGINE OIL
PAN, ADD OIL (PAGE 3-93)".
Even if the machine has not been operated for 500 hours, the
oil and filter cartridge must be replaced when the machine has
been operated for 12 months.
In the same way, even if the machine has not been operated
for 12 months, the oil and filter cartridge must be replaced
when the machine has been operated for 500 hours.
If a quick coupler is installed for draining or adding engine oil, use
the quick coupler.
Quick coupler
Manufacturer: WIGGINS
Model: ON2
Mounting screw
Size: 3/4-14 NPT
NOTICE
If the quick coupler is not installed securely, oil may be sent flying around
during refilling. For safety, use the quick coupler with the box cover closed.
MINING SPECIFICATION MACHINE
MINING SPECIFICATION MACHINE