Komatsu D475A-5E0 Operation & Maintenance Manual page 135

Bulldozer
Hide thumbs Also See for D475A-5E0:
Table of Contents

Advertisement

EXPLANATION OF COMPONENTS
PROCEDURE FOR REPLACING RECEIVER
Replace the receiver once every 2 years.
After replacing the receiver, add compressor oil. Turn the receiver at an angle and measure the oil remaining inside
the receiver, then add the same amount of oil (Denso Oil 6) to fill the receiver.
REMARK
The replacement interval may become shorter depending on the conditions during use.
If the receiver is used when the moisture absorption limit of the desiccant has been exceeded, the refrigerant
circuit may become blocked and cause the compressor to break down.
PRECAUTIONS WHEN REPLACING RECEIVER
If the receiver is left for more than 15 minutes with the blind cover removed, the moisture in the air will be
absorbed, and this will reduce the life of the desiccant. If you remove the blind cover, connect the piping quickly,
evacuate the system and fill with refrigerant.
When removing the refrigerant from the refrigerant circuit, release it gradually from the low pressure side to
prevent oil from flowing out.
CHECK COMPRESSOR BELT TENSION AND REFRIGERANT (GAS) LEVEL
If the compressor belt is loose, or the refrigerant level is low, cooling is not performed efficiently.
For details, see "WHEN REQUIRED (PAGE 4-22)".
CLEANING AIR FILTER
If the air filter for the FRESH or RECIRC air intake becomes clogged, the cooling or heating capacity will drop.
To prevent this, clean the air filter with compressed air once a week.
For details of the cleaning method, see "WHEN REQUIRED (PAGE 4-22)".