Tests Of Technical Ventilation Systems, Gas Warning Devices, Inerting Devices, Devices, Protective Systems Or Safety, Control Or Regulating Devices, And Other Technical Devices For Explosion Protection; Inspection After Changes Requiring Review; Recurring Tests For The Explosive Safety Of The System - Binder VDL Series Operating Manual

Vacuum drying oven with microprocessor program controller mb2
Hide thumbs Also See for VDL Series:
Table of Contents

Advertisement

7.4.2
Tests of technical ventilation systems, gas warning devices, inerting devices,
devices, protective systems or safety, control or regulating devices, and other
technical devices for explosion protection
Test content that has been checked and documented as part of conformity assessment procedures do
not need to be checked again. Verify the plausibility and completeness of documents.
The following points must generally be verified:
• Technical ventilation systems, gas warning devices, inerting devices with regard to their suitability,
their functionality, their interconnections, their installation conditions, their proper condition, and their
installation / assembly
• Devices, protective systems, or safety, control, or regulating devices within the meaning of Directive
2014/34/EU on explosion protection with regard to their proper condition, their suitability, their inter-
connections, their installation conditions, and their installation / assembly
• Safety, control, or regulating devices with relevance for explosion protection, which can also be locat-
ed outside the potentially explosive atmospheres, to determine whether ventilation systems, gas warn-
ing devices, inerting devices ensure the proper exclusion of ignition sources and functionality.
• Calibration of the Pt 100 controller sensor and, if required, subsequent adjustment is to be made be-
fore commissioning the chamber as well as part of the annual maintenance. The procedure is de-
scribed in the Service manual (customer version).
• Ex devices in the sense of TRGS 725, whether they ensure the necessary functional reliability of the
measures.
• Connection elements and other technical devices (such as lightning protection, requirements for
floors) with regard to their condition, their interconnections, and their installation / assembly for explo-
sion safety (e.g. type of installation, insulation resistance of electrical cables and lines)
• Take into account the significant interactions of devices, protective systems, safety, control, or regulat-
ing devices and their connecting elements – with each other and with other system parts. This in-
cludes, for example, testing the equipotential bonding, the involvement of pipes in equipotential bond-
ing, overvoltage protection, and lightning protection, alignment of units (e.g. pump-coupling-motor).
7.5

Inspection after changes requiring review

There is a need for a change requiring review if the explosive safety of the explosive system is affected
by the change. Changes requiring review are evaluated in accordance with applicable national regula-
tions (for Germany in particular: TRBS 1123). Checks after a change requiring review may be limited to
the changes made. Verify whether the system in the potentially explosive area has been changed in ac-
cordance with this regulation and is working properly. See the requirements in Chap. 7.4.
7.6

Recurring tests for the explosive safety of the system

Objective of testing: The recurring tests serve to maintain the explosive safety of the Ex system. Among
other things, the actual state of the system is compared with the target state (according to the explosion
protection document and available test records).