Copy parameter set
Command
Description
Parameter
Acknowledge-
ment
Example
Request parameter set from the BCL 8
Command
Description
Parameter
Acknowledge-
ment
Example
Leuze electronic
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
The command copies complete parameter sets.
'03' copy parameters from the EEPROM into the RAM and initialise all
associated functions
'20' copy standard parameters from the FLASH into the EEPROM and
RAM and initialise all relevant functions
'30' copy parameters from the RAM into the EEPROM
'PSx'
x
status
'0' valid transmission
'1' invalid message
'2' invalid length of message
'3' invalid block check type
'4' invalid block check checksum
'5' invalid data length
'6' invalid message data
'7' invalid start address
'8' invalid parameter set
'9' invalid parameter type
'PC20' loads the default parameters
The command requests parameter data from the BCL 8. Parameter <PS-
type> displays the parameter set from which the data is to be transmitted.
<BCC type><PS type><Start address><Data length>
'PSx'
x
status
'0' valid transmission
'1' invalid message
'2' invalid length of message
'3' invalid block check type
'4' invalid block check checksum
'5' invalid data length
'6' invalid message data
'7' invalid start address
'8' invalid parameter set
'9' invalid parameter type
'PR00102004'
Beginning with address 102, four (004) bytes are read out and transmitted
BCL 8
Online commands
'PC'
'PR'