Connector Unit Ma 8-01; Figure 5.6: Pin Assignment Ma 8-01 - Leuze electronic BCL 8 Series Manual

Barcode reader with integrated decoder
Hide thumbs Also See for BCL 8 Series:
Table of Contents

Advertisement

5.3

Connector unit MA 8-01

The modular connector unit is an optional accessory when connecting a BCL 8 to an RS 485
interface. The RS 485 interface, the switching input and the switching output are all
connected to the MA 8-01. It also supplies voltage to the BCL 8. The MA 8-01 connector unit
offers the following advantages over the installation of the BCL 8 as a stand-alone device:
• M12 socket for switching input and switching output
• M12 connector for RS 485 interface and voltage supply 24VDC
• M12 socket for connection of the BCL 8
PWR IN HOST/RS 485
SW IN/OUT
BPS

Figure 5.6: Pin assignment MA 8-01

Attention!
Protection class IP 67 is achieved only if the connectors and caps are screwed into place!
Leuze electronic
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
= Voltage supply/RS 485 host interface
= Switching input/output
= Connection to BCL 8/BPS 8
Notice!
The SW IN/OUT connection is sealed with a thread plug upon delivery.
M12 socket
(A-coded)
RXD
4
1
SWIN/SWOUT
5
3
2
GND
BPS
Accessories / order codes
M12 socket
(A-coded)
VIN
SWIN
VOUT
4
1
FE
5
3
2
TXD
GND
SWOUT
SW IN/OUT
BCL 8
All dimensions in mm
M12 plug
(A-coded)
A (P)
GND
4
3
FE
5
1
2
VIN
B (N)
PWR IN
HOST/RS485