Accessories / order codes
Switching input
Switching output
Figure 5.1:
5.3.3
MA 8-01 - BCL - connecting the BCL 8 to the MA 8-01
RXD
SWIN/SWOUT
GND
M12 socket
(A-coded)
Figure 5.9: MA 8-01 - Pin assignment BCL
Attention!
Protection class IP 67 is achieved only if the connectors and caps are screwed into place!
The BCL 8 is connected to the MA 8-01 via the connection cable KB 008-1000/2000/3000
(AA/AR). The voltage supply is connected via the PWR IN HOST/RS 485 socket.
26
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Electrical connection MA 8-01
BCL (5-pin socket, A-coded)
Pin
VIN
4
1
1
5
2
3
2
TXD
3
BPS
4
5
Thread
Name
Supply voltage for BCL 8
VIN
approx. +5.2VDC
TXD
Transmission line RS 232
GND
Supply voltage 0VDC
RXD
Receiving line RS 232
SWIN/
Programmable switching input/output of the
SWOUT
BCL 8
FE
Functional earth (housing)
BCL 8
Remark
Leuze electronic