3.2

Stand alone operation

The BCL 8 barcode reader is operated as a "stand-alone" device. It is equipped with a five-
core cable with open ends or a 5-pin M12 connector for the electrical connection of the
supply voltage, the interface and the switching input.
With MA 8.1 connector unit
The MA 8.1 connector unit simplifies the electrical installation of the barcode reader in stand-
alone operation with an RS 232 interface.
For details on the connector units, see chapter 5.
With MA 8-01 connector unit
The MA 8-01 connector unit simplifies the electrical installation of the barcode reader in
stand-alone operation with an RS 485 interface.
For details on the connector units, see chapter 5.
3.3

Daisy chain network

A daisy chain is a network based on the RS 232 interface. All devices, which consist of a
transmitter and a receiver, are connected to one another to form a ring. The transmitter of
one device is directly connected to the receiver of the next device until all devices are
connected together to form a ring. One device performs the task of the host system.
Ideally, all BCL 8 devices are to be connected to one another with MA 8.1 connector units
so that:
• the voltage supply of the BCL 8/MA 8.1 is ensured.
• TxD to RxD of the RS 232 is established from one BCL 8 to the next (host).
• the switching outputs and inputs are connected (optional).
A maximum of seven BCL 8 devices may be operated in the daisy chain together with one
host. Further information is available from your Leuze sales office.