Accessories / order codes
5.2.4

MA 8.1 - BCL - connecting the BCL 8 to the MA 8.1

RXD
SWIN/SWOUT
GND
M12 socket
(A-coded)

Figure 5.5: MA 8.1 - Pin assignment BCL

Attention!
Protection class IP 67 is achieved only if the connectors and caps are screwed into place!
The BCL 8 is connected to the MA 8.1 via the connection cable KB 008-1000/2000/3000
(AA/AR). The voltage supply is connected via the PWR IN HOST/RS 232 socket.
Attention!
It is absolutely necessary to connect functional earth, since all electrical interference (EM
pick-up) is discharged via the functional earth connection.
22
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
BPS (5-pin socket, A-coded)
Pin
VIN
4
1
1
5
2
3
2
TXD
3
BCL 8
4
5
Thread
Name
Supply voltage for BCL 8
VIN
+4.9 ... +5.4VDC
TXD
Transmission line RS 232
GND
Supply voltage 0VDC
RXD
Receiving line RS 232
SWIN/
Programmable switching input/output of the
SWOUT
BCL 8
FE
Functional earth (housing)