Important parameters
10.6
Sensor tab
Figure 10.8: Sensor tab
Invert
Enable
Debounce time
Delay on time
Pulse duration
Delay off time
Notice!
If the switch-off delay is activated, the parameter "pulse duration" should be "0".
Function
Attention!
Depending on wiring, either a switching input or a switching output is available on the BCL 8.
50
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Here, the input level can be inverted.
Switching input enabled or disabled.
This time period must lapse until the trigger signal is regarded as
valid.
The trigger signal is passed on delayed by the specified time period.
If the value is higher than "0": duration of the activation, regardless of
how long the trigger signal has been present.
After the end of the trigger signal, the pulse is extended internally by
this time period.
Event that is started when the switching input is activated.
BCL 8
Leuze electronic