Leuze electronic BCL 8 Series Manual page 57

Barcode reader with integrated decoder
Hide thumbs Also See for BCL 8 Series:
Table of Contents

Advertisement

Online commands
autoConfig
Command
Description
Parameter
Acknowledge-
ment
Description
56
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Activates or deactivates the 'autoConfig' function. Certain label reading
parameters are programmed automatically in the setup by the labels
which are read while the 'autoConfig' function is active.
'+'
activates 'autoConfig'
'/'
rejects the last code read
'-'
deactivates 'autoConfig' and stores the decoded data in the current
parameter set.
'CSx'
x
status
'0' valid 'CA' command
'1' invalid command
'2' autoConfig could not be activated
'3' autoConfig could not be deactivated
'4' result could not be deleted
'xx yy zzzzzz'
xx
Code type of the read code
'01' 2/5 Interleaved
'02' Code 39
'06' UPC (A, E)
'07' EAN
'08' Code 128, EAN 128
'09' Pharmacode
'10' EAN/UPC
'11' Codabar
'12' Code 93
yy
No. of digits of the read code
zzzzzz
Contents of the decoded label. The ↑ appears if the label was not
correctly read.
BCL 8
'CA'
Leuze electronic

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcl 8 s m 0 seriesBcl 8 s m 2 seriesBcl 8 s n 0 seriesBcl 8 s n 2 seriesBcl 8 s m 102Bcl 8 s n 102 ... Show all

Table of Contents