Ma 8-01 - Bcl - Connecting The Bcl 8 To The Ma 8-01; Figure 5.2: Electrical Connection Ma 8-01; Figure 5.1: Ma 8-01 - Pin Assignment Bcl - Leuze electronic BCL 8 Series Original Operating Instructions

Bar code reader with integrated decoder
Hide thumbs Also See for BCL 8 Series:
Table of Contents

Advertisement

Switching input
Switching output
Figure 5.2:
5.3.3

MA 8-01 - BCL - connecting the BCL 8 to the MA 8-01

RXD
SWIN/SWOUT
GND
M12 socket
Figure 5.1:
ATTENTION!
Degree of protection IP 67 is achieved only if the connectors and caps are screwed into
place!
Leuze electronic
Electrical connection MA 8-01
BPS (5-pin socket, A-coded)
Pin
VIN
4
1
1
5
2
3
2
TXD
3
4
BPS
5
Thread
MA 8-01 - Pin assignment BCL
Name
Supply voltage for BCL 8
VIN
approx. +5.2VDC
TXD
RS 232 transmission line
GND
Supply voltage: 0VDC
RXD
RS 232 receiving line
SWIN/
Programmable switching input/output of the
SWOUT
BCL 8
FE
Functional earth (housing)
BCL 8
Accessories/order codes
Comment