Leuze
electronic
4

Technical Data

4.1
Technical Data

4.1.1 Data Sheet BCL 90 CAT M 100 / BCL 90 CAT N 100 / BCL 90 CAT F 100

Model
Type
Reading window
Laser diode (wavelength)
Service life of the laser diode
Laser class of the device
Focus control
Number of
distance configurations
Focus adjustment time
Focus trigger
Useful opening angle
Scanning/decoding frequency 600 ... 1200 Hz
Resolution
DOF
Bar code print contrast (PCS)
External light tolerance
Number of bar codes per scan 1 ... 12 (standard decoder), 1 ... 5 (CRT decoder)
Number of bar codes per
2)
scan gate time
Types of bar code
(CRT decoder)
Bar code length
Print ratio
Number of multiple readings
Optical indicators
Read clocking
Data interface "host"
Data transmission rate
Protocols
Physical configurations
Data interface "service"
Table 4.1: Technical specifications BCL 90 CAT M 100 / N 100 / F 100
Leuze electronic
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
BCL 90 CAT M 100
Medium Density
Line scanner, without heater
frontal
red light (
= 650 nm)
l
MTBF 20,000 h
Class 2 (acc. to DIN EN 60825-1), safety disconnection of the
laser diode after 10 min
autofocus, alternatively event-driven focus position switching
max. 8
20 ms (typically)
ˆ
switched inputs "SE 2... SE 6"/ data interface/ timer
max. 60° (frontal reading window)
0.25 ... 1.0 mm
see reading field diagram starting from page 34
60%
˜
2000 lx (on bar code)
1 ... 50 (auto-discriminating)
Code 39, Code 128, Code 93, Codabar, EAN, EAN 128, UPC,
2/5 Interleaved
max. 50 characters (max. 600 characters for all bar codes per scan
gate time taken together)
2:1 ... 3:1
1 ... 99
4 LED function indicators
switched input "SE 1"/ free-oscillating/ serial interface/ MSP/TCP
RS 232 or RS 422/485, adjustable data output format
300 ... 57 600 bits/ s
Leuze standard, Leuze network multiNet plus and 3964(R)
stand alone, network (bus)
RS 232, 9600 baud, 8 data bits, no parity, 1 stop bit,
predefined output format
Technical Description BCL 90
BCL 90 CAT N 100
High Density
1)
0.17 ... 0.4 mm
Technical Data
BCL 90 CAT F 100
Low Density
0.35 ... 1.2 mm
27